数值
产品分类 光电元件 >> 防静电控制产品
描述 防静电控制产品 JEWEL WKSTATION CONT MINI MONITOR
19218 PDF下载
制造商 SPI Westek
产品 Monitors
类型 ESD Event, Workstation
颜色
大小

19218供应商

公司名
电话
深圳市兴合盛科技发展有限公司 0755-83350789 销售经理:马先生
北京京华特科技有限公司 010-86398446-806 张小姐/韩先生
深圳市众多星电子有限公司 13425282350 欧先生
深圳市佳斯泰科技有限公司 13612973190 廖先生
深圳市奥伟斯科技有限公司 0755-83254770 江小姐 ADS触摸芯片一级代理

19218价格

价格 单价(USA) 总价(USA)

19218相关资料

型号
生产厂商(品牌)
功能描述
021200563591 3M Electronic Specialty 防静电控制产品 THERMLLY CNDCTV TRAN 1-1/2 in. X 36 Yards
8841 3M Electronic Specialty 防静电控制产品 RUBBER TABLE ROLL BLUE 2’ x 24’
TM24600L3BL 3M Electronic Specialty 防静电控制产品 3 LAYER ROLL VINYL BLUE 2’ x 50’
8204-3LFM 3M Electronic Specialty 防静电控制产品 3 LAYER FLOOR MAT BLUE VINYL 4’ x 6’
8861 3M Electronic Specialty 防静电控制产品 RUBBER TABLE ROLL BLUE 3’ x 24’
37055 Protektive Pak 防静电控制产品 BOX W/FOAM ESD 7X5X2.5
37005 Protektive Pak 防静电控制产品 7 x 3-1/2 x 1
94240 SPI Westek 防静电控制产品 Power Supply
06722 SPI Westek 防静电控制产品 LABELS 2" X 2" 500 ROLL
1900 7X15 3M Electronic Specialty 防静电控制产品 CONDUCTIVE BAG 7x15

19218代理商

19218 PDF资料

属性/相关PDF资料
参数
型号 19218
厂商 Desco
文件页数 1/4页
文件大小 0K
描述 MONITOR WORKSTATION JEWEL MINI
19218-0108 COPPER ALLOY, TIN FINISH, WIRE TERMINAL
19218-11 SWITCH DISCONNECT 125A 600V RED
19219 MONITOR GROUND HUB US
19221-0230 CONN RING TONGUE TERM #1/4 4AWG
19221-0231 CONN RING TONGUE TERM #5/16 4AWG
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website: Desco.com
TB-3050 Page 1 of 4
2014 DESCO INDUSTRIES, INC.
Employee Owned
Jewel Workstation Continuous Mini Monitor
Operation, Installation and Maintenance
Description
The Jewel Workstation Continuous Mini Monitor
independently monitors the operator and the
worksurface. The instant an operator’s wrist strap or
cord fails, the monitor will issue audible and visual
alarms alerting the user of the problem. In the same
manner, the unit also confirms that a path to ground
of less than 500 megohms exists from the ESD
worksurface.
The Jewel Workstation Continuous Monitor is a Single
Conductor Impedance Sensing Continuous Monitor
which per ESD Handbook TR20.20 section 5.3.9.2.1 “a
small AC voltage is used in a detection circuit designed
to eliminate false alarms and adjustment. They use the
phase difference between current and voltage to detect
changes in impedance of the grounding cord, wristband
and person. No adjustments are required.”
Per ESD Handbook ESD TR20.20 section 5.3.2.4.4,
“Typical test programs recommend that wrist straps that
are used daily should be tested daily. However, if the
products that are being produced are of such value that
knowledge of a continuous, reliable ground is needed,
and then continuous monioring should be considered or
even required.”
Advantages Of Continuous Monitoring
Over Periodic Testing
“When considering constant [or continuous] monitors,
the equipment cost including the wrist strap,
maintenance and training cost, labor time for performing
wrist strap tests, and the potential failures due to non-
functional wrist straps should be considered.
TECHNICAL BULLETIN TB-3050
April 2014
Figure 1. Desco 19218 Jewel Workstation Continuous
Mini Monitor
A broken wrist strap may expose products to ESD
over an entire shift if it is checked only at shift change
with wrist strap checker.” (ESD TR 12-01 Section 4.2
Selection Considerations)
The Jewel Workstation Continuous Monitor eliminates
the need for periodic wrist strap tests and logging.
Continuous monitoring is superior to periodic or pulsed
testing, and can save a significant amount of money
in testing costs and rejected product. Periodic testing
detects failures after ESD susceptible products way
have been manufactured. The costs of dealing with
the resulting catastrophic or latent defects can be
considerable. Jewel Workstation Continuous Mini
Monitors eliminate the need for operaters to test wrist
straps and log the results; by their function, these
monitors satisfy the ISO 9000 and ANSI/ESD S20.20
test logging. ANSI/ESD S20.20 Section 6.2.2.2
Personnel Grounding Guidance states “A log should be
maintained which verifies that personnel have tested
their personal grounding devices.” Per ANSI/ESD-S1.1
Annex A Section 6.1.3 “Daily (wrist strap system) testing
may be omitted if constant monitoring is used.” Per
ANSI/ESD-S1.1 Annex A Frequency of Functional
Testing, “The wrist strap system should be tested daily
to ensure proper electrical value. Daily testing may be
omitted if constant monitoring is used.”
Park Snap
The audible alarm is designed to alert both operator and
supervisor. The Park Snap feature provides a means
for an operator to disconnect when normally leaving
the work area, without the audible alarm sounding, and
wrist cord storage (visual red LED will illuminate). When
the operator touches the Park Snap, the audible alarm
is disabled for about 8-10 seconds. The operator can
remove the wrist strap cord and attach socket of the
cord to Park Snap for storage. The coil cord may also
be removed from the jack on the Jewel monitor without
the alarm sounding. Once the coil cord is in the park
position, the operator ground status light will remain red.
Wave Distortion Detection Technology
Provides True 100% Continuous Monitoring
Wave distortion impedance circuitry monitors current /
voltage phase shifts and provides true 100% continuous
monitoring. Electrical current will lead voltage at various
points due to the combinations of resistance and
capacitive reactance. By monitoring these “distortions”
or phase shifts, the Jewel Workstation Continuous Mini
Monitor will reliably determine if the circuit is complete.
Made in the