参数资料
型号: 1111XFREQ3AA
厂商: VECTRON INTERNATIONAL
元件分类: XO, clock
英文描述: CRYSTAL OSCILLATOR, CLOCK, 24 MHz - 100 MHz, TTL OUTPUT
封装: DIP-14
文件页数: 15/19页
文件大小: 1082K
代理商: 1111XFREQ3AA
SIZE
CODE IDENT NO.
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
A
00136
N/A
OS-68338
I
5
4.1.4 Packages. Packages are procured that meet the construction, lead materials and finishes as
specified in MIL-PRF-55310. Package lots are upscreened in accordance with the
requirements of MIL-PRF-38534 as applicable.
4.1.5 Traceability. Active device lots are homogenous and traceable to the manufacturer’s
individual wafer. Crystals are traceable to the quartz bar and the processing details of the
autoclave lot, as applicable. All other elements and materials are traceable to their incoming
inspection lots.
4.2
Mechanical.
4.2.1 Package Outline. Table 1 links each Hi-Rel Standard Model Number of this specification to a
corresponding package style. Mechanical Outline information of each package style is found
in the referenced Figure.
4.2.2 Thermal Characteristics. The worst case thermal characteristics of each package style are
found in Table 4.
4.3
Electrical.
4.3.1 Input Power. Devices are designed for standard 5.0 volt dc operation, ±10%. Optional 3.3
Vdc (±10%) input performance for ACMOS output conditions. Current is measured, no load,
at maximum rated operating voltage.
4.3.2 Temperature Range. Operating range is -55°C to +125°C.
4.3.3 Frequency Tolerance. Initial accuracy at +23°C is ±15 ppm maximum. Frequency-
Temperature Stability is ±50 ppm maximum from +23°C reference. Frequency-Voltage
Tolerance is ±4 ppm maximum.
4.3.4 Frequency Aging. Aging limits, and when tested in accordance with MIL-PRF-55310 Group B
inspection, shall not exceed ±1 ppm the first 30 days, ±5 ppm Year 1 and ±2 ppm per year
thereafter.
4.3.4.1 Frequency Aging Duration Option. By customer request, the Aging test may be terminated
after 15 days if the measured aging rate is less than half of the specified aging rate. This is a
common method of expediting 30-Day Aging without incurring risk to the hardware and used
quite successfully for numerous customers. It is based on the ‘least squares fit’ determinations
of MIL-PRF-55310 paragraph 4.8.35. The ‘half the time/half the spec’ limit is generally
conservative as roughly 2/3 of a unit’s Aging deviation occurs within that period of time.
Vectron’s automated aging systems take about 6 data points per day, so a lot of data is
available to do very accurate projections, much more data than what is required by MIL-PRF-
55310. The delivered data would include the Aging plots projected to 30 days. If the units
would not perform within that limit then they would continue to full 30 Day term. Please
相关PDF资料
PDF描述
1101VFREQ3AC CRYSTAL OSCILLATOR, CLOCK, 24 MHz - 100 MHz, ACMOS OUTPUT
1109C24M00000BA CRYSTAL OSCILLATOR, CLOCK, 24 MHz, TTL OUTPUT
1109D4M00000BB CRYSTAL OSCILLATOR, CLOCK, 4 MHz, TTL OUTPUT
1109E0M35000BB CRYSTAL OSCILLATOR, CLOCK, 0.35 MHz, TTL OUTPUT
1113R85M00000AD CRYSTAL OSCILLATOR, CLOCK, 85 MHz, ACMOS OUTPUT
相关代理商/技术参数
参数描述
1111Y1000100FQT 功能描述:CAP CER HIGH Q 1111 制造商:knowles syfer 系列:* 零件状态:在售 标准包装:1,000
1111Y1000100GQT 功能描述:CAP CER HIGH Q 1111 制造商:knowles syfer 系列:* 零件状态:在售 标准包装:1,000
1111Y1000100JQT 功能描述:CAP CER HIGH Q 1111 制造商:knowles syfer 系列:* 零件状态:在售 标准包装:1,000
1111Y1000100KQT 功能描述:CAP CER HIGH Q 1111 制造商:knowles syfer 系列:* 零件状态:在售 标准包装:1,000
1111Y1000101FQT 功能描述:CAP CER HIGH Q 1111 制造商:knowles syfer 系列:* 零件状态:在售 标准包装:1,000