7
AMP M Series
Pin and Socket Connectors
Catalog 82003
Dimensions are in millimeters
Dimensions are shown for
USA: 1-800-522-6752
South America: 55-11-3611-1514
Revised 06-08
and inches unless otherwise
reference purposes only.
Canada: 1-905-470-4425
Hong Kong: 852-2735-1628
specified. Values in brackets are
Specifications subject
Mexico: 01-800-733-8926
Japan: 81-44-844-8013
www.tycoelectronics.com
equivalent U.S. Customary Units.
to change.
C. America: 52-55-5-729-0425
UK: 44-141-810-8967
NOTE: All part numbers
are RoHS Compliant
Contract Carrying Capabilities
The total current capacity of
each contact in a given con-
nector is dependent upon the
heat rise resulting from the
combination of electrical
loads of the contacts in the
connector arrangement and
the maximum ambient tem-
perature in which the
connector will be operating.
Caution must be taken to
ensure that this combination
of conditions does not cause
the internal temperature of
the connector to exceed the
maximum operating temper-
ature of the housing material.
Several variables which must
be considered when deter-
mining this maximum current
capability for your applica-
tion are:
Connector Size - In general,
with more circuits in a con-
nector, less current per
contact can be carried.
Current Load Distribution -
Spreading those lines with
greater current loads
through-out the connector,
particularly around the
outer perimeter, will
enhance heat dissipation.
Ambient Temperature -
With higher ambient
temperatures, less current
can be carried.
Current Rating Verification
Can a contact rated at 10
amps carry 10 amps?
Maybe yes, but probably not.
The reason lies in the test
conditions used to rate the
contact. If these conditions
do not adequately reflect the
application conditions, the
actual allowable current lev-
els may be lower than
specified levels. For example,
many manufacturers, includ-
ing Tyco, test a single contact
in air. This gives an accurate
measure of the basic current-
carrying capacity of the
contact. Use the contact
alone in air and it can cer-
tainly carry 10 amperes. Use
it in a multi-position connec-
tor surrounded by other
current-carrying contacts or
in high ambient temperatures,
and the contact should carry
less current.
Similarly, as the contact ages
and stress relaxation, environ-
mental cycling, and other
degradation factors take their
toll, the contact’s current-
carrying capacity decreases.
A prudent design must set
current levels for such end-of-
design-life (EODL) conditions.
Practical current-carrying
capacity is not an absolute,
but an application-dependent
condition.
New Method Simplifies
Ratings
To help the designer set the
appropriate current level,
Tyco has developed a
method of specifying cur-
rent-carrying capacity. This
method takes into account
the various application fac-
tors that influence current
rating.
The method can be summa-
rized as follows:
The contact is aged to
EODL conditions by durabil-
ity cycling, thermal cycling,
and environmental expo-
sure.
The contact’s resistance
stability is verified.
The current necessary to
produce the specified tem-
perature rise is measured.
This T-rise is usually 30°C.
A rating factor is deter-
mined to allow derating of
multiple contacts in the
same housing and for differ-
ent conductor sizes.
Temperature
One other factor influencing
current levels is the maximum
operating temperature, for
example, 105°C. If the appli-
cation has a high ambient
temperature (over 75°C) the
contact’s T-rise is limited by
the maximum operating tem-
perature. For example, an
application temperature of
90°C limits the contact T-rise
to 15°C. Since current pro-
duces heat (the I2R law), the
current must be lowered to
limit the T-rise.
A contact’s T-rise depends
not only on its I2R Joule heat-
ing, but also on its ability to
dissipate the heat. Consider a
contact in a multi-contact
housing. Joule heating in
multiple contacts will raise
the local ambient tempera-
ture. Since the contact will
not be able to dissipate its
own heat as well by convec-
tion, the maximum T-rise will
be realized at a lower current
level. Conse-quently, the
allowable current level must
be lower to maintain an
acceptable T-rise.
For a given connector, the
current level will be set by the
loading density. A connector
containing 50% current-carry-
ing contacts will permit higher
currents (per contact) than a
connector will at 75% loading.
The loading percentage
assumes an even distribution
of contacts within the housing.
If all 10 contacts are grouped
together in one section of a
20-position
connector, the loading density
may approach 100%.
The Importance of EODL
As stated, T-rise in a contact
depends on both resistance
and current. As it ages, a con-
tact’s resistance will increase.
The contact designer will
specify a maximum resistance
for the contact, this level is the
end-of-design-life resistance.
Before the contact is tested
for current, Tyco subjects it to
a sequence of tests that exer-
cises the major failure
mechanisms and thereby sim-
ulates EODL conditions.
Conditioning includes mating
cycling, industrial mixed-flow-
ing gases, humidity and
tempera-ture cycling, and
vibration to sequentially
introduce wear, corrosion,
stress relaxation, and
mechanical disturbance.
75
60
56
50
45
35
23
7.5
60
45
30
15
0
Type XII Upgrade
Size 8 Upgrade
.125 POWERBAND
Contact
Size 8
Type XII
Type I, Type II/III+
Upgrade
Type III+, Type II,
Type III+ Posted
Size 20 Upgrade
20 DF
CONTACT CURRENT GUIDE Maximum Current (Amperes)
13
11.85
Wire Size - Larger wire will
carry more current since it
has less internal resistance
to current flow and gener-
ates less heat. The wire also
conducts heat away from
the connector.
Curr
ent
Carring
Capabilities
相关PDF资料
PDF描述
3-205508-1 M Series Connectors
3-205514-1 M Series Connectors
328663 Multiple Coaxial Contacts (COAXICON)
328664 Multiple Coaxial Contacts (COAXICON)
328666 Multiple Coaxial Contacts (COAXICON)
相关代理商/技术参数
参数描述
193991-4 制造商:TE Connectivity 功能描述:CONTACT PIN 8AWG CRIMP 制造商:TE Connectivity 功能描述:CONTACT, PIN, 8AWG, CRIMP
1939918 功能描述:可插拔接线端子 FK-MCP 1.5/ 2-ST-3 RoHS:否 制造商:Phoenix Contact 产品:Plugs 系列:PTS 端接类型:Spring Cage 位置/触点数量:5 线规量程:26-14 节距:5 mm 电流额定值:10 A 电压额定值:250 V 安装风格: 安装角: 触点电镀:
1939920000 制造商:Weidmuller 功能描述:BCZ 3.81/11/90 SN OR BX
1939921 功能描述:可插拔接线端子 FK-MCP 1,5/ 3-ST-3,5 3P 3.5MM PLUG RoHS:否 制造商:Phoenix Contact 产品:Plugs 系列:PTS 端接类型:Spring Cage 位置/触点数量:5 线规量程:26-14 节距:5 mm 电流额定值:10 A 电压额定值:250 V 安装风格: 安装角: 触点电镀:
193992-4 功能描述:集管和线壳 PIN BODY TYPE XII RoHS:否 产品种类:1.0MM Rectangular Connectors 产品类型:Headers - Pin Strip 系列:DF50 触点类型:Pin (Male) 节距:1 mm 位置/触点数量:16 排数:1 安装风格:SMD/SMT 安装角:Right 端接类型:Solder 外壳材料:Liquid Crystal Polymer (LCP) 触点材料:Brass 触点电镀:Gold 制造商:Hirose Connector