参数资料
型号: 2026-7-A1LF
厂商: Bourns Inc.
文件页数: 1/3页
文件大小: 0K
描述: GAS DISCHARGE TUBE
标准包装: 100
系列: TRIGARD™ 2026
电压 - DC 击穿(标称值): 75V
脉冲放电电流 (8/20us): 20kA
容差: ±20%
极数: 3
故障短路:
安装类型: 表面贴装
封装/外壳: 圆柱形,无引线,3端子
包装: 散装
电流 - AC 放电(标称值): 20A
Features
■ Balanced TRIGARD ?
■ Approximately 8 mm diameter, 11 mm long
■ UL recognized
■ Custom con?gurations available
■ High surge current rating
Applications
■ Telecommunications
■ Industrial electronics
■ Commercial electronics
■ Consumer electronics
■ Automotive, aircraft, military electronics
■ Stable breakdown throughout life
■ RoHS compliant* version available
2026 Series - 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Characteristic
DC Sparkover ±20 % @ 100 V/s
2026-07
75 V
2026-09
90 V
2026-15
150 V
Model No.
2026-20
200 V
2026-23
230 V
2026-25
250 V
2026-26
260V 1
Impulse Sparkover
100 V/μs
1000 V/μs
275 V
700 V
275 V
600 V
350 V
575 V
425 V
625 V
450 V
650 V
475 V
700 V
475 V
700 V
Characteristic
2026-30
2026-35
Model No.
2026-40 2026-42
2026-47
2026-60
DC Sparkover ±20 % @ 100 V/s
300 V
350 V
400 V
420 V
470 V
600 V
Impulse Sparkover
100 V/μs
1000 V/μs
500 V
775 V
625 V
875 V
675 V
925 V
725 V
1000 V
800 V
1100 V
925 V
1250 V
Impulse Transverse Delay.............................................1000 V/μs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10 10 Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage 2 .................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 μs 3 .................................................... 1 operation minimum
20000 A, 8/20 μs ...................................................... > 10 operations
5000 A, 10/350 μs ................................................... 1 operation
1000 A, 10/1000 μs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles 3 ............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................................
40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
? UL recognized component, UL File E153537.
? Model number marking on tube: 26-xxx V.
? The rated discharge current for TRIGARD ? Gas Discharge Tubes is the total current equally divided between each line to ground.
? Sparkover limits after life ±25 %, IR >10 8 Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
? Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
? At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Speci?cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their speci?c applications.
相关PDF资料
PDF描述
SM5S33A-E3/2D TVS 5W 33V 5% DO-218AB
N3793-2202RB CONN HEADER 10POS STR GOLD T/H
2-647135-3 CONN HEADER 3POS MTA-156 STR AU
2-647140-6 CONN HEADER 6POS MTA-156 STR AU
2026-09-C2LF GAS DISCHARGE TUBE 3 POLE
相关代理商/技术参数
参数描述
2026-7-C2FLF 功能描述:GAS DISCHARGE TUBE RoHS:是 类别:过电压,电流,温度装置 >> 气体放电管 (GDT) 系列:TRIGARD™ 2026 标准包装:1 系列:- 电压 - DC 击穿(标称值):- 脉冲放电电流 (8/20us):- 容差:- 极数:- 故障短路:- 安装类型:DIN 轨道 封装/外壳:模块,插入式接线盒 包装:散装 电流 - AC 放电(标称值):- 其它名称:VAL-CP-3C-350 VFVAL-CP-3C-350VF
2026-7-C4FLF 功能描述:GAS DISCHARGE TUBE RoHS:是 类别:过电压,电流,温度装置 >> 气体放电管 (GDT) 系列:TRIGARD™ 2026 标准包装:1 系列:- 电压 - DC 击穿(标称值):- 脉冲放电电流 (8/20us):- 容差:- 极数:- 故障短路:- 安装类型:DIN 轨道 封装/外壳:模块,插入式接线盒 包装:散装 电流 - AC 放电(标称值):- 其它名称:VAL-CP-3C-350 VFVAL-CP-3C-350VF
2026-7-C4LF 功能描述:GAS DISCHARGE TUBE RoHS:是 类别:过电压,电流,温度装置 >> 气体放电管 (GDT) 系列:TRIGARD™ 2026 标准包装:1 系列:- 电压 - DC 击穿(标称值):- 脉冲放电电流 (8/20us):- 容差:- 极数:- 故障短路:- 安装类型:DIN 轨道 封装/外壳:模块,插入式接线盒 包装:散装 电流 - AC 放电(标称值):- 其它名称:VAL-CP-3C-350 VFVAL-CP-3C-350VF
2026-7-CLF 功能描述:GAS DISCHARGE TUBE RoHS:是 类别:过电压,电流,温度装置 >> 气体放电管 (GDT) 系列:TRIGARD™ 2026 标准包装:1 系列:- 电压 - DC 击穿(标称值):- 脉冲放电电流 (8/20us):- 容差:- 极数:- 故障短路:- 安装类型:DIN 轨道 封装/外壳:模块,插入式接线盒 包装:散装 电流 - AC 放电(标称值):- 其它名称:VAL-CP-3C-350 VFVAL-CP-3C-350VF
20268 制造商:HENKEL 功能描述:4013(TM) Prism(R) Instant Adhesive, General-Purpose