参数资料
型号: 270
厂商: TPI (Test Products Int)
文件页数: 2/2页
文件大小: 0K
描述: CLAMP-ON TESTER W/DMM
标准包装: 1
类型: 电流钳表(独立)
技术规格: DMM 函数包含电压、电阻、电容、温度、频率和400A的电流
额定值: CAT III 600V
相关产品: A270-ND - SOFT POUCH FOR 270
其它名称: 290-1421
TPI 270
TPI270
270 Clamp-On Tester General Features and Specifications
FAQ
TPI offers a
complete line
of…
CO, Combustibles &
Combustion (CEA)
Refrigerant Leak
Detectors
Digital Manometers
TemperatureContact
& IR Instruments
IAQ: Air Flow /
Humidity
Handheld
Oscilloscopes
Digital Multimeters
& Clamp-on Meters
Accessories & Kits
Test Products
International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005
USA
503-520-9197
Fax: 503-520-1225
email:
info@tpi-thevalueleader.com
Test Products
International, Ltd.
342 Bronte St. South
Unit 9
Milton, Ontario L9T
5B7
Canada
905-693-8558
Fax: 905-693-0888
email:
info@tpicanada.com
Instrument Specifications
Basic DC Accuracy:
DC Voltage (maximum):
Resolution (maximum):
AC Voltage (maximum):
Resolution (maximum):
DC Amps (maximum):
Resolution (maximum):
AC Amps (maximum):
Resolution (maximum):
Resistance (maximum):
Resolution (maximum):
Frequency (maximum):
Resolution (maximum):
Capacitance (maximum):
Resolution (maximum):
Temperature (maximum)
Resolution (maximum)
Diode:
Continuity:
Agency Approval:
Overall Dimensions:
Weight:
Standard Accessories
GK11M
A085
A270
Optional Accessories
A202
A771
A620
TLS2000RB
Distributed By:
0.5%
600V
0.1mV
600V
0.1mV
400μA
0.01μA
400A
0.01A
40M
0.1
400MHz
0.001KHz
40,000μF
0.001nF
1,000 ° F
0.1 °
Test Current Max 1.5mA
Buzzer sounds at <approx. 35 Response time; 50ms
CEIEC 1010: CATIII; 600V
CULUS 61010
10” x 1.3” x 2.5” (255 x 32.5 x 65mm)
.8 lbs (363g)
Standard K-Kype Thermocouple Probe
(screw
UL Listed Silicone Test Lead Set with Alligator Clips (clip-on)
Soft Carrying Pouch
Line Splitter
Carbon Monoxide Adapter
Pressure Adapter
Deluxe Test Lead Kit
thenon-contact
1. How does 270 voltage
detection work?
This feature allows you to detect the
presence of voltage without contacting
the circuit with the test leads. By
pressing the NCV button and holding the
jaw close to the wire or circuit, the meter
will inform you both audibly and visually
if the circuit is live.
2. What is hi voltage indication?
High voltage indication is an audible and
visual safety alert informing you the test
leads are in contact with a voltage
greater than 30V AC or DC.
3. What is relative mode?
Relative mode allows you to perform
measurements relative to a stored value.
For example, when performing a low
resistance measurement, first touching
the test prods together and pressing the
relative button will subtract the lead
resistance from subsequent
measurements.
4. Is it possible to determine the
maximum current draw on a line that
has loads that vary?
By activating the min/max mode on the
270 it will record the minimum and
maximum current measured. This is
helpful when trying to see what the
maximum load draw is as devices turn
on and off.
5. Can I measure motor start up current
with the TPI 270 clamp-on tester?
Yes, the 270 has a peak hold function
that allows motor start up current to be
captured.
6. Can I test the run and start
capacitors on motors?
The 270 has the ability to measure
capacitors up to 40,000 microfarads in
size.
7. Do I need an adapter to measure
temperature with the 270?
An adapter is not needed to perform
temperature tests with the 270. The 270
accepts K-type thermocouple probes
with a sub-mini connector.
8. What is the value of having an
analog bargraph display?
The analog bargraph allow you to see
rapid signal fluctuations occurring too
To learn about the entire
www.tpi-thevalueleader.com
TestProducts
International UK Ltd.
Longley House, East Park
Crawley, West Sussex
RH10 6AP England
Tel: +44 (0)1293 561212 line of TPI products visit:
Fax: +44 (0)1293813465
contactus@tpieurope.com
Copyright ? 2005 Test Products International, Inc. L 270-1205
fast to be seen on the digital display.
Meters without this feature are unable to
show the presence of rapidly fluctuating
inputs.
9. Is it possible to measure AC amps
on a device that uses a power cord?
Yes, to accomplish this you can use the
TPI line splitter (A202). AC amps must be
measured by isolating a single wire and
the A202 line splitter does this without
damaging the power cord.
相关PDF资料
PDF描述
275 DGTL CLAMP-ON W/11,000 CNT DISP
2765E-33.333300MHZ OSC 33.33330 MHZ SMD S SPCTRM
2814045 MCR PASSIVE ISOLATOR 4-20MA
2833657 PLUG IN MOD 12-24VDC IN
2842-8-2 CORD MINI BANA PLUG PATCH 8" RED
相关代理商/技术参数
参数描述
270 10 ML 制造商:Henkel Corporation / Loctite 功能描述:
270 50ML 制造商:Henkel Corporation / Loctite 功能描述:ADHESIVE LOCTITE 270 50ML
270 BDJ 制造商:Ersa 功能描述:
270.1 制造商:Mentor 功能描述:Bulk 制造商:Mentor Graphics 功能描述:HANDLE ROUND CHROME 55MM 制造商:Mentor Graphics 功能描述:HANDLE, ROUND, CHROME, 55MM 制造商:MENTOR 功能描述:HANDLE, ROUND, CHROME, 55MM; External Height - Imperial:2.6"; External Height - Metric:66mm; External Diameter - Imperial:0.28"; External Diameter - Metric:7mm; External Width - Imperial:0.28"; External Width - Metric:7mm; Handle ;RoHS Compliant: Yes
270.10 制造商:Mentor Graphics 功能描述:HANDLE ROUND 45MM 制造商:Mentor Graphics 功能描述:HANDLE, ROUND, 45MM 制造商:MENTOR 功能描述:HANDLE, ROUND, 45MM; External Height - Imperial:2.17"; External Height - Metric:55mm; External Diameter - Imperial:0.24"; External Diameter - Metric:6mm; External Width - Imperial:0.24"; External Width - Metric:6mm; Handle ;RoHS Compliant: Yes