Rugged Environment
DC-DC Converters <40 W
10 Watt-Family
Edition 2/96 - Melcher AG
6 - 33
MELCHER
The Power Partners.
6.1
Installation Instructions
Isolation Tests
Input to output isolation voltage tests are performed as factory tests (100%) and should not be repeated in the field.
Melcher will not honour any guarantee/warranty claims resulting from high voltage field tests.
Table 8: Isolation test voltage coupling capacitance and insulation resistance
Characteristic
Conditions
IPS
IPW 1
IPZ
Unit
Uis io
Isolation test voltage
AC: 50 Hz,
500
1060
5000
Vrms
Input to output
1 minute
1400
3000
14100
Vpp
DC: 1 second 2
700
1500
7070
V
DC: 1 second 3
800
1700
8000
Cio
Coupling capacitance
typ
1000
40
pF
Ris
Insulation resistance
at 100 V DC
≥1000
M
after 1 minute
1 According to EN 41003 (1993)
2 For production test purposes in accordance with IEC 950/EN 60950
3 Factory test procedure
Connection in Series
If the outputs of one or more units are connected in series
each individual output should be protected by a zener diode
or preferably by a suppressor diode to avoid overvoltages
or reverse polarity at the individual outputs, e.g.: 1N5908
(5 V), BZW04-11 (12 V), BZW04-14 (15 V) or equivalent
types.
Such destructive voltages may occur at switch-on cycle of
the converters, if the output voltages do not rise at the same
time. The "slower" output(s) could be supplied and, as a
result, destroyed by the "faster" output(s) via the load. The
maximum output current is limited by the lowest current
limitation.
Connection in Parallel
Connection of the outputs of one or more units in parallel is
not permitted. The load distribution and the ripple values
could not be controlled.
Cleaning
Two CFC free cleaning solvents have been tested and can
be recommended:
– Prozone from BP
– Zestron from Dr. O. K. Wack Chemie GmbH (Germany)
Submersion of the units in water for rinsing is permitted.
Drying should be done in air only.
Unit 1
Unit 2
+
Uo
Uo
+Vo
Go
–Vo
+Vo
Go
–Vo
Fig. 1
Outputs connected in series
Shutdown Description
The shutdown terminal is used to switch the converter out-
put voltage
Uo on and off (e.g. using an open collector
drive). See "Electrical Input and Output Data".
The output voltage is switched on when the shutdown ter-
minal is open circuit. The output voltage is switched off
when a voltage of –0.3...+2 V is applied to the shutdown
terminal. At the open shutdown pin 10...12 V will appear.
相关PDF资料
PDF描述
48IPW10-05-TC 1-OUTPUT 10 W DC-DC REG PWR SUPPLY MODULE
40IMX70-05-0IG 1-OUTPUT 51 W DC-DC REG PWR SUPPLY MODULE
48IMS7-05-9Z 1-OUTPUT 6.1 W DC-DC REG PWR SUPPLY MODULE
48IMS25-15-9 1-OUTPUT 24 W DC-DC REG PWR SUPPLY MODULE
40IMX15-05-9RZ-G 1-OUTPUT 12.8 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
48IPS3-05-05S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
48IPS3-05-05T 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
48IPS3-05-12S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
48IPS3-05-12T 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
48IPS3-05-15S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC