参数资料
型号: 48IXP3-05-7
厂商: POWER-ONE INC
元件分类: 电源模块
英文描述: 1-OUTPUT 2.5 W DC-DC REG PWR SUPPLY MODULE
封装: PLASTIC, DIL-24/7
文件页数: 6/7页
文件大小: 77K
代理商: 48IXP3-05-7
Board Mountable
DC-DC Converters
IMP 3 Series
Edition 4/04.2001
6/6
Table 8: Pin allocation alternative pinout
Pin
Single output
Dual output
Double output
1
Vi+
2
Vi+
9
––
Go1
10
COM
11
COM
12
Vo––
Vo1
13
Vo+
Vo–
Vo2
15
Vo+
16
––
Go2
20
SD
23
Vi–
24
Vi–
Table 9: Pin allocation industry standard pinout (option S)
Pin
Single output
Dual output
2Vi–
Vi–
3Vi–
Vi–
9
n.c.
COM
10
––
11
n.c.
Vo–
14
Vo+
15
n.c.
16
Vo–
COM
22
Vi+
23
Vi+
Safety and Installation Instructions
Installation Instruction
Installation of the DC-DC converters must strictly follow the
national safety regulations in compliance with the enclo-
sure, mounting, creepage, clearance, casualty, markings
and segregation requirements of the end-use application.
Connection to the system shall be made via a printed circuit
board according to:
Mechanical Data.
The units should be connected to a secondary circuit.
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also
Safety of
operator accessible output circuit.
Input Fuse
To prevent excessive current flowing through the input sup-
ply line in case of a short-circuit across the converter input
an external fuse should be installed in a non earthed input
supply line. We recommend a fast acting fuse F1A for
24 IMP 3 and 24 IXP 3 types and F0.5A for 48 IMP 3 and
48 IXP 3 types..
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
Standards and approvals
The units have been evaluated for:
Building in
Operational insulation input to output
The use in a pollution degree 2 environment
Connecting the input to a secondary circuit which is sub-
ject to a maximum transient rating of 1500 V (IMP 3) or
4000 V (IXP 3).
Protection Degree
The protection degree of the DC-DC converters is IP 40.
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Table 7: Electric strength test voltages, clearance and
creepage distances
Characteristic
Input to output
Output to
Unit
IMP 3
IXP 3
output
Electric strength
1.1
2.5
0.35
kVrms
test voltage 1 s
1.5
3.5
0.5
kV DC
Coupling capacitance
≈40
≈30
pF
Insulation resistance
>1000
>100
M
at 500 V DC
相关PDF资料
PDF描述
40IMX15-05-9RIZ 1-OUTPUT 12.8 W DC-DC REG PWR SUPPLY MODULE
40IMX15-12-12-9RIL 2-OUTPUT 16.8 W DC-DC REG PWR SUPPLY MODULE
48IML10-15-15-3C 2-OUTPUT 10.5 W DC-DC REG PWR SUPPLY MODULE
48IPS10-0505-TB 2-OUTPUT 10 W DC-DC REG PWR SUPPLY MODULE
48SE28S 1-OUTPUT 7 W DC-DC UNREG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
48IXP3-12-12-7 制造商:POWER-ONE 制造商全称:Power-One 功能描述:3 Watt DC-DC Converters
48IXP3-1212-7 制造商:POWER-ONE 制造商全称:Power-One 功能描述:3 Watt DC-DC Converters
48IXP3-12-7 制造商:Power-One 功能描述:
48IXP3-1515-7 功能描述:CONVERT DC/DC +15V, -15V 3W RoHS:否 类别:电源 - 板载 >> DC DC Converters 系列:* 标准包装:5 系列:*
48IXP3-1515-7S 制造商:Power-One 功能描述: