Notes
1. guaranteed by design, not tested.
2. Operation is limited below 16V (see Figure 22).
3. Indefinite short circuit protection not guaranteed above 125°C case.
4. Recovery time is measured from application of the transient to point at which Vout
is within 1% of final value.
5. Tested on release from inhibit.
SINGLE OUTPUT MODELS
MTR283R3S
MTR2805S
MTR2812S
units
parameter
ConDitions
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
output voltage
3.201
3.30
3.399
4.85
5.00
5.15
11.64 12.00 12.36
vDC
output Current
vin = 16 to 40 vDC
0
—
6.06
0
—
5.0
0
—
2.5
a
output poWer
vin = 16 to 40 vDC
0
—
20
0
—
25
0
—
30
W
output ripple
10 khz - 2 mhz
tC = 25°C
—
15
40
—
35
50
—
25
40
mV p-p
tC = -55°C to +125°C
—
50
—
50
90
—
40
90
line regulation 2
vin = 16 to 40 vDC
tC = 25°C
—
5
10
—
10
50
—
10
50
mV
TC = -55°C TO +125°C
—
10
—
15
50
—
15
50
loaD regulation
no loaD to Full
tC = 25°C
—
2
10
—
5
50
—
5
50
mV
TC = -55°C TO +125°C
—
10
—
15
50
—
15
50
input voltage
no loaD to Full
Continuous
16
28
40
16
28
40
16
28
40
vDC
TRANSIENT 50 msec.
—
50
—
50
—
50
v
input Current
no loaD
—
30
75
—
35
75
—
35
75
mA
inhibiteD
—
7
8
—
3
8
—
3
8
input ripple Current
10 khz - 10 mhz
—
25
50
—
20
50
—
20
50
mA p-p
eFFiCienCy
tC = 25°C
74
76
—
76
78
—
80
83
—
%
TC = -55°C TO +125°C
71
—
73
—
77
—
loaD Fault 3
poWer Dissipation
short CirCuit
—
12
—
14
—
12
W
reCovery 1
—
1.4
6
—
1.4
5
—
1.4
5
ms
step loaD response
50% - 100% - 50%
transient
—
±125
±250
—
±200
±300
—
±250
±400
mV pk
reCovery 1, 4
—
200
—
60
200
—
60
200
s
step line
response 1
16 - 40 -16 vDC
transient
—
±300
—
±200
±300
—
±400
±500
mV pk
reCovery 4
—
300
—
300
—
300
s
start-up 5
Delay
—
1.4
5
—
1.4
5
—
1.4
5
m sec
overshoot
Full loaD 1
—
0
50
—
0
50
—
0
120
mV pk
no loaD 1
—
33
150
—
50
250
—
120
600
CapaCitive loaD 1
tC = 25°C
no eFFeCt on DC
perFormanCe
—
300
—
300
—
300
F
Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, free run, unless otherwise specified.
Crane Aerospace & Electronics Power Solutions
MTR Single, Dual and Triple DC/DC Converters
28 VOlT INPuT – 30 WaTT
www.craneae.com/interpoint
Page 6 of 22