Features
s
Low-cost plastic case
s
Compact design requires minimal real estate space
s
Suitable for products that must conform
to FCC and FTZ regulations
s
Wide variety of circuit and filtering options
s
Good filtering characteristics for both normal mode
and common mode
s
Epoxy molded for reliability
s
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 63)
Applications
s
Personal computers and peripherals
s
Digital equipment
s
Industrial equipment
s
Vending machines
s
Office equipment
62-PQF*
Series
62-PPF*
Series
62-PRF*
Series
* Bleeder Resistor is available only for
62-P(Q/R/P)F-XXX-X-12
R
L1
CX
CY
Circuit Diagrams
Power Line Filters
Single Stage
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated current
Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
62-PPF/PQF/PRF Series
Power
Line
Filters
62
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Model
Rated Voltage
Rated
Leakage Current
Capacitance
Inductance
Temperature
(@ 50/60Hz)
Current
(Max.)
CY
CX
(L1)
Rise (Max.)
Specifications
62-PQF-020-5-11
0.50mA
62-PQF-020-5-12
2A
0.1uF
3A
6A
30°C
15mH
8mH
2.1mH
1A
3A
250VAC
62-PPF-020-5-11
62-PPF-020-5-12
62-PQF-030-5-11
62-PQF-030-5-12
62-PPF-030-5-11
62-PPF-030-5-12
62-PQF-060-5-11
62-PQF-060-5-12
62-PPF-060-5-11
62-PPF-060-5-12
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-020-5-11
62-PRF-020-5-12
62-PRF-030-5-11
62-PRF-030-5-12
3300pF
2A
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
486uH
97uH
181uH
Tested and found to be
IAW VDE 0565 Part 3