71M6515H Demo Board User’s Manual
System Constants Area (9):
This area consists of two entry fields to the right of the Temperature Compensation area. Entries in these
fields determine the system parameters of the Demo Board.
GUI Element
(Label)
IMAX
VMAX
Default
208A
600V
Function
IMAX is the RMS meter current that results in 250mV peak signal at the
ADC input. This variable reflects the scaling implemented by the voltage
sensing resistors of the Demo Board.
Note: When using shunt resistors as current sensors, IMAX must be
calculated as (V ppmax = 250mV):
V pp max
IMAX =
R sh ? 2
VMAX is the RMS meter voltage that results in 250mV peak signal at the
ADC input. This variable reflects the design of the current sensing circuitry
of the Demo Board, assuming a 2000:1 current transformer.
Warning Thresholds Area (10):
This area consists of seven entry fields to the right of the Temperature Compensation area.
GUI Element
(Label)
Creep
Vrms Peak
Irms Peak
Sag (Vpk)
SagCnt
Starting V
Starting I
Revision 2.0
Default
27000
733.2
254.2
79.9
80
39.974
0.048
Function
Determines the creep threshold. For each phase, if WSUM_X and
VARSUM_X of that phase are less than the value in the CREEP field, the
contents of I 2 h, Wh, and VARh for that phase will be set to zero for the
whole accumulation interval. If all phases are below the creep threshold,
the CREEP bit in the status word is set. The default value is 6000.
Threshold for over-voltage alarms, measured in Vrms.
Threshold for over-current alarms, measured in Arms.
Determines the voltage sag threshold. The peak voltage must exceed
the voltage entered in this field at least once each SAG_CNT samples in
order to prevent a sag warning.
Values can be entered directly in Volts. The GUI will round the entered
value to the next possible value that can be represented with the
resolution used for this parameter.
Determines the sag alarm setting. Sag must persist SAG_CNT *397 μ s
before the sag alarm is generated. Allowed range is 1 to (2 15 -1). Default
is 80 (31.7ms).
Determines the voltage below which the calculation of frequency, zero
crossings and voltage phase is suppressed.
Determines the current below which the calculation of current-related
values is suppressed.
18 of 66
? Copyright 2005 TERIDIAN Semiconductor Corporation
相关PDF资料
PDF描述
71M6521FE-DB BOARD DEMO FOR 71M6521FE
71M6531F-DB BOARD DEMO 71M6531F
71M6533-DB BOARD DEMO 71M6533
71M6534H-DB BOARD DEMO 71M6534H
71M6541F-DB DEMO BOARD 71M6541F
相关代理商/技术参数
参数描述
71M6515H-IGT 制造商:Maxim Integrated Products 功能描述:METERING FRONT END - Rail/Tube
71M6515H-IGT/F 功能描述:计量片上系统 - SoC Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6515H-IGTR 制造商:Maxim Integrated Products 功能描述:71M6515H-IGT - T/REEL - Tape and Reel 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Energy Meter IC
71M6515H-IGTR/F 功能描述:计量片上系统 - SoC Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6515H-IGTW/F 功能描述:计量片上系统 - SoC Energy Meter IC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel