参数资料
型号: 76601/1C
厂商: Murata Power Solutions Inc
文件页数: 3/3页
文件大小: 0K
描述: XFRMR 1:1 1916UH 17.5VUS B
产品培训模块: Magnetics Offering
产品目录绘图: 766 Series Top
766 Series Side
标准包装: 50
系列: 766
变压器类型: 隔离和数据接口(封装式)
电感: 1.9mH
匝数比 - 主:副: 1 : 1
E.T.: 17.5V µS
安装类型: 通孔
尺寸/尺寸: 12.70mm L x 8.89mm W
高度 - 座高(最大): 6.35mm
其它名称: 811-1282-5
766 Series
Pulse Transformers
PACKAGE SPECIFICATIONS (continued)
PIN CONNECTION STYLE - 6 PIN DIP (TOP VIEW)
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand
Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a speci?ed time, across a component designed to provide electrical
isolation, to verify the integrity of that isolation.
All products in this series are 100% production tested at their stated isolation voltage.
A question commonly asked is, “What is the continuous voltage that can be applied
across the part in normal operation?”
For a part holding no speci?c agency approvals both input and output should normally
be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test
voltage represents a measure of immunity to transient voltages and the part should
never be used as an element of a safety isolation system. The part could be expected
to function correctly with several hundred volts offset applied continuously across the
isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form
a barrier between these circuits and any user-accessible circuitry according to safety
standard requirements.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mans?eld, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component
can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. This series has toroidal isolation transformers,
with no additional insulation between primary and secondary windings of enameled
wire. While parts can be expected to withstand several times the stated test voltage,
the isolation capability does depend on the wire insulation. Any material, including this
enamel (typically polyurethane) is susceptible to eventual chemical degradation when
subject to very high applied voltages thus implying that the number of tests should be
strictly limited. We therefore strongly advise against repeated high voltage isolation
testing, but if it is absolutely required, that the voltage be reduced by 20% from speci-
?ed test voltage.
This consideration equally applies to agency recognized parts rated for better than
functional isolation where the wire enamel insulation is always supplemented by a
further insulation system of physical spacing or barriers.
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Speci?cations are subject to change without
notice. ? 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
KMP_766C_D01 Page 3 of 3
相关PDF资料
PDF描述
MC13917-434EVK IC MC13917 EVB 434MHZ
MC13917-350EVK IC MC13917_350_EVK
MC13917-1900EVK IC MC13917_1900_EVK
MC13852-434EVK IC MC13852 EVB 434MHZ
MC13851-2140EVK IC MC13851_2140_EVK
相关代理商/技术参数
参数描述
766011HVRC 制造商:Murata Power Solutions 功能描述:
766012 制造商:CANDD 制造商全称:C&D Technologies 功能描述:Pulse Transformers
76601-2 制造商:未知厂家 制造商全称:未知厂家 功能描述:Pulse Transformers
7660120 制造商:CANDD 制造商全称:C&D Technologies 功能描述:Pulse Transformers
76601-20 制造商:未知厂家 制造商全称:未知厂家 功能描述:Pulse Transformers