845 Series
souriau
cable fittings
00 - connector without fitting*
15- back nut (corresponding to contact arrangement)
17- straight fitting with cable clamp (supplied with a grommet seal)
12 - straight fitting for metal solder sleeve or heat shrink sleeving
14 - elbow fitting for metal solder sleeve or heat shring sleeving
36 - elbow fitting with cable (supplied with a grommet seal corresponding to contact arrangement)
special types
38 - conduit tube fitting, plain
41 - conduit tube fitting, braid
contact type
3- pin, solder
7- socket, solder
1- pin, crimp
5- socket, crimp
shell style
1- square flange receptacle
8- plug
5- in-line receptacle
contact layouts
see table p 196
Applications
For all purposes in severe mechanical
environment.
Power applications up to 200 A.
Description
Shells in steel
Wide choice of contacts and contact layouts
Environmental or sealed versions
Environmental
Temperature range :
-40°C to +85°C (+125°C peak)
Humidity :
to NFC 20603 for 56 days
Salt spray :
to NFC 20603 for 96 hours
Fluid sealing :
immersed :
4 meters for 10 hours (standard version)
6 meters for 24 hours (sealed version)
water jet :
impact pressure 1 kg/cm2
for 15 minutes
Standards
NFL 54120
GAM/T1 list
Characteristics
Mechanical
Endurance :
500 matings
Shock :
NFC 20616 level 50A
Vibration :
NFC 20616 level 55/10
Contact retention (min) :
1
50N
3.5
100N
1.5
70N
5
150N
2.5
80N
10
200N
( in mm)
basic series
845
-21
-8
3
12
Without grommet seal
Ordering information
Electrical
Maximum contact current rating :
1
7.5A
3.5
40A
1.5
11A
5
60A
2.5
25A
10
200A
Test voltage :
2800 Vrms/50Hz
(except 1mm contact : 1500 Vrms)
Insulation resistance :
between contacts and earth at normal
ambient temperature :
≥ 5000 M
Contact resistance :
1
3 m
3.5
0.35 m
1.5
1.5 m
5
0.25 m
2.5
0.6 m
10
0.08 m
* a connector may be ordered in this condition but cannot be utilised without specifying separately.
example : connector
845-21-83-00
fitting
845-20-00-12
note : insulators and contacts are packed separately from connectors. Correct location of the insulator is made during assembly.
Style 1 receptacles are supplied complete with panel seals. The grommet seals provided with style 17 and 36 cable clamp fittings are not
intended to be bonded to connector insulators.
195