Small power relay
Limiting continuous current 30A
Minimal weight
Low noise operation
Wave (THT) and reow (THR/pin-in-paste) solderable versions
For twin version refer to Double Micro Relay K
For latching (bistable) version refer to Micro Relay K Latching
For surface mounted technology refer to SMT versions
Typical applications
Car alarm, door control, door lock, hazard warning signal, heated front/rear
screen, immobilizer, lamps front/rear/fog light, interior lights, seat control,
sun roof, turn signal, window lifter, wiper control.
Micro Relay K (THT – THR)
Automotive Relays
PCB Single Relays
Contact Data
Typical applications
Resistive/inductive load
Wiper load
Flasher load
Lamp load
V23086-*100*-A403
V23086-*1*02-A803
V23086-C100*-A602
V23086-***21-A502
Contact arrangement
1 form C, 1 CO
1 form A, 1 NO
Rated voltage
10/12VDC
NO/NC
Rated current
30/25A
30A
Limiting continuous current
23°C
30/25A
30A
85°C
20/15A
20A
Limiting making current
40A1)
70A2)
100A2)
Limiting breaking current
30A
Contact material
AgSnO2
Min. recommended contact load
1A at 5VDC3)
Initial voltage drop at 10A, typ./max.
30/300mV
Operate/release time
typ. 3/1.5ms4)
Electrical endurance
cyclic temperature -40°C, +25°C, +85°C
form C contact (CO) at 14VDC
motor reverse blocked,
wiper,
25A, 0.77mH
25A make/5A break,
>1x105 ops.
generator peak,
20A on NC,1mH
>1x106 ops.
form A contact (NO) at 14VDC
resistive 20A
asher up to 3x21W,
lamp 100A inrush,
>3x105 ops.
turn and hazard signal
10A steady state
in sequence
>1x105 ops.
>2x106 ops.
Mechanical endurance
>5x106 ops.
Max. DC load breaking capacity
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors veried for 1000 switching events.
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum
3s for a make/break ratio of 1:10.
2) Corresponds to the peak inrush current on initial actuation (cold lament).
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reducesthe lifetime
caused by increased erosion and/or higher risk of contact tack welding.