SHIPBOARD/ AC POWER BUS VOLTAGE SUPPRESSOR
1
05026.R6 2/07
www.protekdevices.com
60KS200C
thru
90KS200C
APPLICATIONS
AC Power Protection
Shipboard (Line-Line) Protection
Differential AC Power Bus
Aircraft AC Power Bus
IEC COMPATIBILITY (EN61000-4)
Meets the Following Military Specifications:
- DOD-STD-1399
- MIL-STD-704A
60 & 90 kilowatts Peak Pulse Power per Line (tp=1.2/50s)
Each Device 100% Tested
200 Volts Bidirectional
MECHANICAL CHARACTERISTICS
Hermetically Sealed Glass to Metal Sub-Assemblies
Weight 50 grams (Approximate)
Flammability Rating UL 94V-0
Device Marking: Logo & Part Number
Screening Available Upon Request - The 60 & 90KS series can be screened upon
request for military requirements in accordance with MIL-PRF-19500 (applicable test).
Standard screening is available based on the following options:
H1 - Submodule Screening per test plans 05231 & 05232
H2 - Submodule & Module Screening per test plan 05233
H3 - Submodule & Module Screening, Module Group B & C Lot Testing
per test plans 05234 & 05235
05026
60KS200C
90KS200C
Operating Temperature
SYMBOL
VALUE
-55 to 150
°C
-55 to 150
UNITS
T
L
T
STG
PARAMETER
Storage Temperature
Peak Pulse Power (tp = 1.2/50s) - See Fig. 1
PPP
60 & 90
kilowatts
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
Steady State Power Disspiation @ 50°C
T
A
10.0
Amps