参数资料
型号: A1190LLHLT-T
厂商: Allegro Microsystems Inc
文件页数: 12/18页
文件大小: 383K
描述: IC HALL EFFECT SWITCH SOT-23-3
标准包装: 1
类型: 单极开关
电源电压: 3 V ~ 24 V
电流 - 电源: 5mA
输出类型: 数字
特点: 可编程
工作温度: -40°C ~ 150°C
封装/外壳: SOT-23W
供应商设备封装: SOT-23W
包装: 标准包装
其它名称: 620-1390-6
Programmable, Chopper-Stabilized,
Two Wire Hall-Effect Switches
A1190, A1192,
and A1193
12
Allegro MicroSystems, LLC
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
To correctly address the fuses to be blown, the code represent-
ing the required parameter value must be translated into a binary
number. For example, as shown in figure 7, decimal code 5 is
equivalent to the binary number 101. Therefore bit 2 must be
addressed and blown, the device power supply cycled, and then
bit 0 must be addressed and blown. The order of blowing bits,
however, is not important. Blowing bit 0 first, and then bit 2 is
acceptable.
Note: After blowing, the programming is not reversible, even
after cycling the supply power. Although a register bit field fuse
cannot be reset after it is blown, additional bits within the same
register can be blown at any time until the device is locked. For
example, if bit 1 (binary 10) has been blown, it is still possible to
blow bit 0. The end result would be binary 11 (decimal code 3).
Locking the Device
After the required code for each parameter is programmed, the
device can be locked to prevent further programming of any
parameters. To do so, perform the following steps:
1. Ensure that the C
BLOW
 capacitor is mounted.
2. Select the Programming Lock register (key 7).
3. Select Blow mode (key 9).
4. Address bit 3 (001000) by sending four V
PM
 pulses.
5. Send one Blow pulse, at I
PP
 and SR
BLOW
, and sustain it for
t
BLOW
.
6. Delay for a t
LOW
 interval, then power-down.
7. Optionally check all fuses.
Fuse Checking
Incorporated in the A119x family is circuitry to simultaneously
check the integrity of the fuse bits. The fuse checking feature is
enabled by using the Fuse Check register (selection key 7), and
while in Try mode, applying the codes shown in table 2. The
register is only valid in Try mode and is available before or after
the Programming Lock bit is set.
Setting the fuse threshold high checks that all blown fuses are
properly blown. Setting fuse threshold low checks all un-blown
fuses are properly intact. The supply current increases by 250 糀
if a marginal fuse is detected. If all fuses are correctly blown or
fully intact, there will be no change in supply current.
Additional Guidelines
The additional guidelines in this section should be followed to
ensure the proper behavior of these devices:
" A 0.1 糉 blowing capacitor, C
BLOW
, must be mounted between
the VCC pin and the GND pin during programming, to ensure
enough current is available to blow fuses.
" The power supply used for programming must be capable of
delivering at least V
PH
 and 175 mA.
" Be careful to observe the t
LOW
 delay time before powering
down the device after blowing each bit.
" Lock the device (only after all other parameters have been pro-
grammed and validated) to prevent any further programming of
the device.
B
OP
 Selection
Selecting B
OP
 should be done in two stages. First, Try mode
should be used to adjust B
OP
 and monitor the output state. Then
the optimum B
OP
 is set permanently using Blow mode.
Use the B
OP
 Trim Up Counting register to increase the B
OP
 selec-
tion by one Magnetic Step Size, Step
BOP
 , increment with each
bit field pulse (see figure 8). Use the B
OP
 Trim Down Counting
register to decrease the B
OP
 selection by one Step
BOP
 with each
bit field pulse (see figure 9). As an aid to programming, when
using down-counting method, the A119x automatically inverts
the bit field selection (code 0 in down-counting sets the bit field
value 111111, and the actual bit field value decreases until code
63 sets bit field value 000000).
Note that the release point, B
RP
 , is a value below B
OP
 . The
difference is specified by the Hysteresis, B
HYS
, which is not
programmable.
相关PDF资料
PDF描述
2N7002-7-F MOSFET N-CH 60V 115MA SOT23-3
14A-2.5R-12 XFRMR PWR 115/230V 6.3V .40A
R9G01612XX RECTIFIER 1600V 1200A
DC-ANT-24DP-10 ANTENNA 2.4GHZ DIPOLE 2DBI 10PC
14A-2.5R-16 XFRMR PWR 115/230V 8.0V .30A
相关代理商/技术参数
参数描述
A1190LLHLX-T 功能描述:IC SWITCH HALL EFFECT UNI SOT-23 RoHS:是 类别:传感器,转换器 >> 磁性 - 霍尔效应,数字式开关,线性,罗盘 (IC) 系列:- 标准包装:1 系列:- 传感范围:20mT ~ 80mT 类型:旋转 电源电压:4.5 V ~ 5.5 V 电流 - 电源:15mA 电流 - 输出(最大):- 输出类型:数字式,PWM,8.5 位串行 特点:可编程 工作温度:-40°C ~ 150°C 封装/外壳:20-SSOP(0.209",5.30mm 宽) 供应商设备封装:20-SSOP 包装:Digi-Reel® 其它名称:AS5132-HSST-500DKR
A1190LUA-T 功能描述:IC SW HALL EFFECT CHOPPER 3SIP RoHS:是 类别:传感器,转换器 >> 磁性 - 霍尔效应,数字式开关,线性,罗盘 (IC) 系列:- 标准包装:1 系列:- 传感范围:20mT ~ 80mT 类型:旋转 电源电压:4.5 V ~ 5.5 V 电流 - 电源:15mA 电流 - 输出(最大):- 输出类型:数字式,PWM,8.5 位串行 特点:可编程 工作温度:-40°C ~ 150°C 封装/外壳:20-SSOP(0.209",5.30mm 宽) 供应商设备封装:20-SSOP 包装:Digi-Reel® 其它名称:AS5132-HSST-500DKR
A1190LUBTN-T 功能描述:2-WIRE FIELD PROGRAMMABLE SWITCH 制造商:allegro microsystems, llc 系列:* 零件状态:新产品 标准包装:1
A1191 制造商:Quick 功能描述:SIP 25L 25mm Nozzle for 21-13205 and 21-13210 制造商:QUICK 功能描述:SIP 25L NOZZLE FOR QUICK957/957D
A-1191-1 功能描述:固态继电器-工业安装 DC SOLENOID RoHS:否 制造商:Crydom 控制电压范围:4 VDC to 32 VDC 负载电压额定值:7 VDC to 72 VDC 负载电流额定值:160 A 触点形式: 输出设备:SSR 安装风格:Panel