–3–
REV. 0
AD53513
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD53513 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
ABSOLUTE MAXIMUM RATINGS
1
Power Supply Voltage
+V
S
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 V
–V
S
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –7 V
+V
S
to –V
S
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
Inputs
DATA,
DATA
, INH,
INH
, RLD, VBB . . . . . . . +5 V, –3 V
DATA to
DATA
, INH to
INH
, RLD, VBB . . . . . . . . .
±
3 V
V
H
, V
L
, V
T
to GND . . . . . . . . . . . . . . . . . . . . . . +7 V, –2 V
V
H
to V
L
(V
H
– V
T
) and (V
T
– V
L
) . . . . . . . . . . . . . . . .
±
9 V
Outputs
V
OUT
Short Circuit Duration . . . . . . . . . . . . . . . Indefinite
2
V
OUT
Range in Inhibit Mode
V
HDCPL
. . . . . Do Not Connect Except for Capacitor to V
CC
V
LDCPL
. . . . . Do Not Connect Except for Capacitor to V
EE
THERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 V, 0 V
Environmental
Operating Temperature (Junction) . . . . . . . . . . . . . . . 175
°
C
Storage Temperature . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
Lead Temperature (Soldering, 10 sec)
3
. . . . . . . . . . . 260
°
C
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Absolute maximum limits apply
individually, not in combination. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
2
Output
short circuit protection is guaranteed as long as proper heat sinking is
employed to ensure compliance with the operating temperature limits.
3
To ensure lead coplanarity (
±
0.002 inches) and solderability, handling with bare
hands should be avoided and the device should be stored in environments at 24
°
C
±
5
°
C (75
°
F
±
10
°
F) with relative humidity not to exceed 65%.
WARNING!
ESD SENSITIVE DEVICE
ORDERING GUIDE
Shipment Method,
Quantity Per
Shipping Container
Package
Description
Package
Option
Model
AD53513JSQ
100-Lead LQFP-CDQUAD
Tray, 90 Pieces
SQ-100
Parameter
Min
Typ
*
Max
Unit
Test Conditions
DYNAMIC PERFORMANCE, INHIBIT
Delay Time, Active to Inhibit
Delay Time, Inhibit to Active
I/O Spike
Output Capacitance
1.5
0.7
2.5
1.7
ns
ns
mV p-p
pF
Measured at 50%, V
H
= +2 V, V
L
= –2 V, V
T
= –2 V
Measured at 50%, V
H
= +2 V, V
L
= –2 V, V
T
= –2 V
V
H
= 0 V, V
L
= 0 V, V
T
= –2 V
Driver Inhibited
<200
6
DYNAMIC PERFORMANCE, V
TERM
Delay Time, Active to V
TERM
Delay Time, V
TERM
to Active
Overshoot, Undershoot, and Preshoot
V
TERM
to V
L
or V
H
0.50
0.45
1.30
1.25
ns
ns
Measured at 50%, V
H
= +0.8 V, V
L
= –0.8 V, V
T
= 0 V
50
Terminated
V
L
= –2 V, V
H
= +2 V, V
T
= 0 V
V
L
= –0.8 V, V
H
= +0.8 V, V
T
= 0 V
Output Terminated 50
±
6%/
±
75
mV
POWER SUPPLIES
Total Supply Range
Positive Supply
Negative Supply
Positive Supply Current
Negative Supply Current
Total Power Dissipation
Temperature Sensor Gain Factor
15
9
–6
V
V
V
mA
mA
W
μ
A/K
570
570
8.6
1.0
R
LOAD
= 4.2 k
, V
SOURCE
= 9 V
NOTES
Connecting or shorting the decoupling capacitors to ground will result in the destruction of the device.
*
Typical parameters are not production tested but guaranteed through characterization.
Specifications subject to change without notice.