参数资料
型号: AD7685BRMZRL7
厂商: Analog Devices Inc
文件页数: 10/28页
文件大小: 0K
描述: IC ADC 16BIT PSEUDO-DIFF 10-MSOP
产品培训模块: Power Line Monitoring
Motor Control
设计资源: Parametric Measurement Unit and Supporting Components for PAD Appls Using AD5522 and AD7685 (CN0104)
Integrated Device Power Supply for PAD with Output Voltage Range 0 V to 25 V (CN0130)
标准包装: 1,000
系列: PulSAR®
位数: 16
采样率(每秒): 250k
数据接口: DSP,MICROWIRE?,QSPI?,串行,SPI?
转换器数目: 1
功率耗散(最大): 15mW
电压电源: 模拟和数字
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 10-TFSOP,10-MSOP(0.118",3.00mm 宽)
供应商设备封装: 10-MSOP
包装: 带卷 (TR)
输入数目和类型: 1 个伪差分,单极
配用: EVAL-AD7685CBZ-ND - BOARD EVAL FOR AD7685
AD7685
Rev. C | Page 18 of 28
CS MODE 3-WIRE, NO BUSY INDICATOR
This mode is usually used when a single AD7685 is connected
to an SPI-compatible digital host.
The connection diagram is shown in Figure 34, and the
corresponding timing is given in Figure 35.
With SDI tied to VIO, a rising edge on CNV initiates a
conversion, selects the CS mode, and forces SDO to high
impedance. Once a conversion is initiated, it will continue to
completion irrespective of the state of CNV. For instance, it
could be useful to bring CNV low to select other SPI devices,
such as analog multiplexers, but CNV must be returned high
before the minimum conversion time and held high until the
maximum conversion time to avoid the generation of the BUSY
signal indicator. When conversion is completed, the AD7685
enters the acquisition phase and powers down. When CNV
goes low, the MSB is output onto SDO. The remaining data bits
are then clocked by subsequent SCK falling edges. The data is
valid on both SCK edges. Although the rising edge can be used
to capture the data, a digital host using the SCK falling edge will
allow a faster reading rate provided it has an acceptable hold
time. After the 16th SCK falling edge or when CNV goes high,
whichever is earlier, SDO returns to high impedance.
CNV
SCK
SDO
SDI
DATA IN
CLK
CONVERT
VIO
DIGITAL HOST
AD7685
02
96
8-
03
2
Figure 34. CS Mode 3-Wire, No BUSY Indicator
Connection Diagram (SDI High)
SDO
D15
D14
D13
D1
D0
tDIS
SCK
1
2
3
14
15
16
tSCK
tSCKL
tSCKH
tHSDO
tDSDO
CNV
CONVERSION
ACQUISITION
tCONV
tCYC
ACQUISITION
SDI = 1
tCNVH
tACQ
tEN
02
96
8-
0
33
Figure 35. CS Mode 3-Wire, No BUSY Indicator Serial Interface Timing (SDI High)
相关PDF资料
PDF描述
VE-B2R-MW-F1 CONVERTER MOD DC/DC 7.5V 100W
VE-B3B-IV-S CONVERTER MOD DC/DC 95V 150W
VI-26R-MY CONVERTER MOD DC/DC 7.5V 50W
VE-B33-IV-S CONVERTER MOD DC/DC 24V 150W
AD9214BRSZ-RL80 IC ADC 10BIT 80MSPS 28-SSOP T/R
相关代理商/技术参数
参数描述
AD7685CCPZ-R2 制造商:Analog Devices 功能描述:ADC SGL SAR 250KSPS 16BIT SERL 10LFCSP - Tape and Reel
AD7685CCPZRL 功能描述:IC ADC 16BIT SAR 250KSPS 10LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
AD7685CCPZRL7 功能描述:IC ADC 16BIT SAR 250KSPS 10LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 其它有关文件:TSA1204 View All Specifications 标准包装:1 系列:- 位数:12 采样率(每秒):20M 数据接口:并联 转换器数目:2 功率耗散(最大):155mW 电压电源:模拟和数字 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:48-TQFP 供应商设备封装:48-TQFP(7x7) 包装:Digi-Reel® 输入数目和类型:4 个单端,单极;2 个差分,单极 产品目录页面:1156 (CN2011-ZH PDF) 其它名称:497-5435-6
AD7685CRM 制造商:Analog Devices 功能描述:ADC Single SAR 250ksps 16-bit Serial 10-Pin MSOP
AD7685CRMRL7 制造商:Analog Devices 功能描述:ADC Single SAR 250ksps 16-bit Serial 10-Pin MSOP T/R