REV. G
–22–
AD7711
Figures 12a and 12b show timing diagrams for reading from the
AD7711 in external clocking mode. In Figure 12a, all the data is
read from the AD7711 in one operation. In Figure 12b, the data
is read from the AD7711 over a number of read operations. Both
read operations show a read from the AD7711’s output data
register. A read from the control register or calibration registers is
similar, but, in these cases, the
DRDY line is not related to the
read function. Depending on the output update rate, it can go
low at any stage in the control/calibration register read cycle
without affecting the read, and its status should be ignored. A
read operation from either the control or calibration registers
must always read 24 bits of data.
Figure 12a shows a read operation from the AD7711 where
RFS remains low for the duration of the data-word transmission.
With
DRDY low, the RFS input is brought low. The input
SCLK signal should be low between read and write operations.
RFS going low places the MSB of the word to be read on the
serial data line. All subsequent data bits are clocked out on a
high to low transition of the serial clock and are valid prior to
the following rising edge of this clock. The penultimate falling
edge of SCLK clocks out the LSB and the final falling edge
resets the
DRDY line high. This rising edge of DRDY turns off
the serial data output.
Figure 12b shows a timing diagram for a read operation where
RFS returns high during the transmission of the word and
returns low again to access the rest of the data-word. Timing
parameters and functions are very similar to that outlined for
Figure 12a, but Figure 12b has a number of additional times to
show timing relationships when
RFS returns high in the middle
of transferring a word.
RFS should return high during a low time of SCLK. On the
rising edge of
RFS, the SDATA output is turned off. DRDY
remains low and will remain low until all bits of the data-word
are read from the AD7711, regardless of the number of times
RFS changes state during the read operation. Depending on the
time between the falling edge of SCLK and the rising edge of
RFS, the next bit (BIT N+1) may appear on the data bus before
RFS goes high. When RFS returns low again, it activates the
SDATA output. When the entire word is transmitted, the
DRDY line will go high, turning off the SDATA output as shown
in Figure 12a.
t20
SDATA (O)
SCLK (I)
RFS (I)
A0 (I)
DRDY (O)
t22
t24
t25
t26
t27
t29
t28
t23
t21
THREE-STATE
MSB
LSB
Figure 12a. External Clocking Mode, Output Data Read Operation
t20
SDATA (O)
SCLK (I)
RFS (I)
A0 (I)
DRDY (O)
t22
t24
t25
t26
t27
t24
t25
THREE-STATE
MSB
t30
t31
BIT N
BIT N+1
Figure 12b. External Clocking Mode, Output Data Read Operation (
RFS Returns High during Read Operation)
相关PDF资料
PDF描述
AD7712AR IC ADC SIGNAL COND LC2MOS 24SOIC
AD7713AN IC ADC 24BIT SIGMA-DELTA 24-DIP
AD7714ARS-3 IC ADC 24BIT SIGMA-DELTA 28SSOP
AD7715ANZ-3 IC ADC 16BIT SIGMA-DELTA 16DIP
AD7716BSZ IC ADC 22BIT SIGMA-DELTA 44-MQFP
相关代理商/技术参数
参数描述
AD7711ANZ 功能描述:IC ADC 24BIT RTD I SOURCE 24-DIP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 其它有关文件:TSA1204 View All Specifications 标准包装:1 系列:- 位数:12 采样率(每秒):20M 数据接口:并联 转换器数目:2 功率耗散(最大):155mW 电压电源:模拟和数字 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:48-TQFP 供应商设备封装:48-TQFP(7x7) 包装:Digi-Reel® 输入数目和类型:4 个单端,单极;2 个差分,单极 产品目录页面:1156 (CN2011-ZH PDF) 其它名称:497-5435-6
AD7711ANZ 制造商:Analog Devices 功能描述:IC ADC 24-BIT SIGMA DELTA
AD7711AQ 功能描述:IC ADC 24BIT RTD I SOURCE 24CDIP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:- 位数:14 采样率(每秒):83k 数据接口:串行,并联 转换器数目:1 功率耗散(最大):95mW 电压电源:双 ± 工作温度:0°C ~ 70°C 安装类型:通孔 封装/外壳:28-DIP(0.600",15.24mm) 供应商设备封装:28-PDIP 包装:管件 输入数目和类型:1 个单端,双极
AD7711AR 功能描述:IC ADC 24BIT RTD I SOURCE 24SOIC RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:- 位数:14 采样率(每秒):83k 数据接口:串行,并联 转换器数目:1 功率耗散(最大):95mW 电压电源:双 ± 工作温度:0°C ~ 70°C 安装类型:通孔 封装/外壳:28-DIP(0.600",15.24mm) 供应商设备封装:28-PDIP 包装:管件 输入数目和类型:1 个单端,双极
AD7711AR-REEL 功能描述:IC ADC 24BIT RTD I SOURCE 24SOIC RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:- 位数:14 采样率(每秒):83k 数据接口:串行,并联 转换器数目:1 功率耗散(最大):95mW 电压电源:双 ± 工作温度:0°C ~ 70°C 安装类型:通孔 封装/外壳:28-DIP(0.600",15.24mm) 供应商设备封装:28-PDIP 包装:管件 输入数目和类型:1 个单端,双极