参数资料
型号: ADM1021AARQZ
厂商: ON Semiconductor
文件页数: 12/16页
文件大小: 0K
描述: IC SENSOR TEMP DUAL3/5.5V 16QSOP
产品变化通告: MFG CHG Notification ADI to ON Semi
标准包装: 98
功能: 温度监控系统(传感器)
传感器类型: 内部和外部
感应温度: 0°C ~ 100°C,外部传感器
精确度: ±1°C 本地,±5°C 远程
拓扑: ADC,比较器,多路复用器,寄存器库
输出类型: SMBus?
输出警报:
输出风扇:
电源电压: 3 V ~ 5.5 V
工作温度: 0°C ~ 100°C
安装类型: 表面贴装
封装/外壳: 16-SSOP(0.154",3.90mm 宽)
供应商设备封装: 16-QSOP
包装: 管件
其它名称: ADM1021AARQZ-ND
ADM1021AARQZOS
ADM1021A
1
9
1
9
SCLK
SDATA
A6
A5
A4
A3
A2
A1
A0
R/W
D7
D6
D5
D4
D3
D2
D1
D0
FRAME 2
START BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
ACK. BY
ADM1021A
ACK. BY
ADM1021A
ADDRESS POINTER REGISTER BYTE
STOP BY
MASTER
Figure 15. Writing to the Address Pointer Register Only
1
9
1
9
SCLK
SDATA
A6
A5
A4
A3
A2
A1
A0 R/W
D7
D6
D5
D4
D3
D2
D1
D0
FRAME 2
START BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
ACK. BY
ADM1021A
NO ACK. BY
MASTER
DATA BYTE FROM ADM1021A
STOP BY
MASTER
Figure 16. Reading Data from a Previously Selected Register
When reading data from a register there are two
possibilities:
1. If the ADM1021A’s address pointer register value
is unknown or not the desired value, it is first
necessary to set it to the correct value before data
can be read from the desired data register. This is
done by performing a write to the ADM1021A as
before, but only the data byte containing the
register read address is sent, because data is not to
be written to the register. This is shown in
Figure 15.
A read operation is then performed consisting of
the serial bus address, R/W bit set to 1, followed
by the data byte read from the data register. This is
shown in Figure 16.
2. If the address pointer register is known to be
ALERT Output
The ALERT output goes low whenever an out-of-limit
measurement is detected, or if the remote temperature sensor
is open-circuit. It is an open drain and requires a 10 k W
pullup to V DD . Several ALERT outputs can be wire-ANDed
togethe r so the common line goes low if one or more of the
ALERT outputs goes low.
The ALERT output can be used as an interrupt signal to a
processor, or it can be used as an SMBALERT. Slave devices
on the SMBus cannot normally signal to the master that they
want to talk, but the SMBALERT function allows them to do
so.
One or more ALERT outputs are connected to a common
SMBALERT line connected to the master. When the
SMBALERT line is pulled low by one of the devices, the
following procedure occurs, as shown in Figure 17.
START
already at the desired address, data can be read
from the corresponding data register without first
writing to the address pointer register, so Figure 15
can be omitted.
MASTER RECEIVES SMBALERT
ALERT RESPONSE
ADDRESS
MASTER SENDS
ARA AND READ
COMMAND
RD ACK
DEVICE
ADDRESS
DEVICE SENDS
ITS ADDRESS
NO
ACK
STOP
NOTES:Although it is possible to read a data byte from a data
register without first writing to the address pointer register,
if the address pointer register is already at the correct value,
it is not possible to write data to a register without writing to
the address pointer register; this is because the first data
byte of a write is always written to the address pointer
register.
Remember that the ADM1021A registers have different
addresses for read and write operations. The write address
of a register must be written to the address pointer if data is
to be written to that register, but it is not possible to read data
from that address. The read address of a register must be
written to the address pointer before data can be read from
that register.
Figure 17. Use of SMBALERT
1. SMBALERT is pulled low.
2. Master initiates a read operation and sends the
alert response address (ARA = 0001 100). This is
a general call address that must not be used as a
specific device address.
3. The device whose ALERT output is low responds
to the alert response address and the master reads
its device address. The address of the device is
now known and it can be interrogated in the usual
way.
4. If more than one device’s ALERT output is low,
the one with the lowest device address has priority,
in accordance with normal SMBus arbitration.
http://onsemi.com
12
相关PDF资料
PDF描述
ADM1032ARM-REEL IC TEMP MONITOR 85DEF 8MSOP
ADM1032ARM-1REEL7 IC TEMP MONITOR 105DEF 8MSOP
ADT7463ARQ-REEL7 IC SENSOR TEMP FAN-CTRL 24QSOP
AGL060V2-CSG121 IC FPGA IGLOO 1.2-1.5V CSG121
ADT7463ARQ-REEL IC SENSOR TEMP FAN-CTRL 24QSOP
相关代理商/技术参数
参数描述
ADM1021AARQZ-R 功能描述:板上安装温度传感器 PIN COMP TO ADM1021 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
ADM1021AARQZ-R7 功能描述:板上安装温度传感器 PIN COMP TO ADM1021 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
ADM1021AARQZ-REEL 功能描述:IC SENSOR TEMP DUAL3/5.5V 16QSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1021AARQZ-REEL7 功能描述:IC SENSOR TEMP DUAL3/5.5V 16QSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1021ARQ 功能描述:IC SENSOR TEMP DUAL3/5.5V 16QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6