ADMC300
–5–
REV. B
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADMC300 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
ABSOLUTE MAXIMUM RATINGS*
Supply Voltage (V
DD
) . . . . . . . . . . . . . . . . . .–0.3 V to +7.0 V
Supply Voltage (AV
DD
) . . . . . . . . . . . . . . . . .–0.3 V to +7.0 V
Input Voltage . . . . . . . . . . . . . . . . . . . . –0.3 V to V
DD
+ 0.3 V
Output Voltage Swing . . . . . . . . . . . . . –0.3 V to V
DD
+ 0.3 V
Operating Temperature Range (Ambient) . . . –40
°
C to +85
°
C
ORDERING GUIDE
Temperature
Range
–40
°
C to +85
°
C
Instruction
Rate
Package
Description
Package
Option
Model
ADMC300BST
ADMC300-ADVEVALKIT
ADMC300-PB
25 MHz
80-Lead Plastic Thin Quad Flatpack (TQFP)
Development Tool Kit
Evaluation/Processor Board
ST-80
Parameter
Min
Max
Unit
Serial Ports
Timing Requirements:
t
SCK
t
SCS
t
SCH
t
SCP
Switching Characteristics:
t
CC
t
SCDE
t
SCDV
t
RH
t
RD
t
SCDH
t
SCDD
SCLK Period
DR/TFS/RFS Setup before SCLK Low
DR/TFS/RFS Hold after SCLK Low
SCLK
IN
Width
50
5
10
20
ns
ns
ns
ns
CLKOUT High to SCLK
OUT
SCLK High to DT Enable
SCLK High to DT Valid
TFS/RFS
OUT
Hold after SCLK High
TFS/RFS
OUT
Delay from SCLK High
DT Hold after SCLK High
SCLK High to DT Disable
0.25 t
CK
0
0.25 t
CK
+ 15
ns
ns
ns
ns
ns
ns
ns
20
0
20
0
20
Specifications subject to change without notice.
t
SCP
t
SCP
CLKOUT
SCLK
DR
RFS
IN
TFS
IN
DT
t
CC
t
CC
t
SCS
t
SCH
t
RD
t
RH
RFS
OUT
TFS
OUT
t
SCDV
t
SCDE
t
SCDH
t
SCDD
t
SCK
Figure 2. Serial Ports
Storage Temperature Range . . . . . . . . . . . . –65
°
C to +150
°
C
Lead Temperature (5 sec) . . . . . . . . . . . . . . . . . . . . . .+280
°
C
*Stresses greater than those listed above may cause permanent damage to the
device. These are stress ratings only; functional operation of the device at these
or any other conditions greater than those indicated in the operational sections of
this specification is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
WARNING!
ESD SENSITIVE DEVICE