参数资料
型号: AM2540-9PD4AHFU
元件分类: 电源模块
英文描述: 2-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
封装: 168.50 X 111.20 MM, 38.70 MM HEIGHT, METAL, CASE M02, MODULE
文件页数: 6/24页
文件大小: 536K
代理商: AM2540-9PD4AHFU
Rugged Environment
DC-DC Converters <100 W
M-Family
Edition 2/96 - Melcher AG
7 - 15
MELCHER
The Power Partners.
7.1
Supplementary Data
Important Advice
Testing by applying AC voltages will result in high and
dangerous leakage currents through the Y-capacitors
(see fig. 1). Melcher will not honour any guarantee/war-
ranty claims resulting from high voltage field tests. Ref-
erence is also made to chapter: Safety and Installation
Instructions.
Isolation
Input to output electric strength tests, in accordance with
the safety standards IEC 950, EN 60950, VDE 0805 and
EN 41003 are performed as factory tests and should not be
repeated in the field.
Fig. 12
Definition of leakage currents and measurement proce-
dure by means of the measuring device MD
Table 15: Leakage currents
Characteristic
Class I (LM)
Class II (LMZ)
Unit
a) permissible according to IEC 950
a)
b)
a)
b)
b) value at 264 V, 50 Hz
max
Earth leakage current
3.5
1.4
mA
Enclosure leakage current
0.25
0.03
Output leakage current
0.25
0.005
0.25
0.15
MD for enclosure
leakage current
MD for output
leakage current
MD for earth
leakage current
MD for output
leakage current
connection to case
LMZ 1000…LMZ 3000
LM 1000…LM 3000
+
+
1500
150 nF
V
MD
Leakage Currents in AC-DC operation
Leakage currents will flow due to internal leakage capa-
citances and RFI suppression Y-capacitors. The current
values are proportional to the mains voltage and nearly pro-
portional to the mains frequency and are specified at an in-
put condition of 264 V/50 Hz where phase, neutral and pro-
tective earth are correctly connected as required for class I
equipment. Under test conditions the leakage currents flow
through a measurement circuit, consisting of a 1500
re-
sistance with a 150 nF capacitor connected in parallel. The
voltage drop across this element is measured and the cur-
rent value calculated from the measured voltage divided by
1500
.
If inputs of M-units are connected in parallel, their individual
leakage currents are added.
Table 14: Electric strength test voltage, insulation resistance, clearance and creepage distances
Characteristic
Input/Output
Input/Case
Output/Case Output/Output Unit
a) values according to IEC 950,
Class I
Class II
b) Product's performance
a)
b)
a)
b)
a)
b)
a)
b)
a)
b)
Electric strength
DC: 1 s
4243 1 56001
2122
2800
4243
5600
707
1414
300
V
test voltage
AC: 50 Hz, 1 min
3000 1 4000 1
1500
2000
3000
4000
500
1000
200
Insulation resistance
at 500 V DC
≥300
≥300
≥300
≥100
M
Clearance and
AM/BM
4.0
5.0
2.0
4.0
5.0
1.0
2.0
0.9
mm
Creepage distances
C...LM and C/D/LMZ
4.0
8.0
2.0
4.0
5.0
1.0
2.0
0.9
1 Only subassemblies performance in accordance with IEC 950
相关PDF资料
PDF描述
AM3040-7PD5AHFU 3-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
ASM63813UK17TD4G 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO5
ASM63813UK17TD7G-T 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO5
ASM63813UK23TD6F-T 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO5
ASM63813UK23TD7G 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO5
相关代理商/技术参数
参数描述
AM256 制造商:CHENYI 制造商全称:Shanghai Lunsure Electronic Tech 功能描述:PRESS FIT AUTOMOTIVE RECTIFIER
AM25A2 制造商:ANDERS ELECTRONICS 功能描述:METER 78X60 0-1MA 制造商:ANDERS ELECTRONICS 功能描述:METER, 78X60, 0-1MA 制造商:ANDERS ELECTRONICS 功能描述:METER, 78X60, 0-1MA; Terminal Resistance Range:-; Meter Function:DC Milliamps; Meter Range:-; Accuracy Class:1.5; Coil Resistance:200ohm; External Length / Height:60mm; External Width:78mm; Meter Size/Dimensions:60mm x 78mm x 16m ;RoHS Compliant: Yes
AM25A2 制造商:ANDERS ELECTRONICS 功能描述:METER 78X60 0-1MA
AM25-A3-A-60-2E 制造商:HEINEMANN / EATON 功能描述:
AM25-A8-A-50-10 制造商:HEINEMANN / EATON 功能描述: 制造商:Heinemann / Eaton 功能描述: