AQ8
3 A type
Notes: *1. Refer REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*2. Refer to REFERENCE DATA “2. Characteristics of non-repetitive surge current vs. carrying time”.
*3. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2) Random type
2 A type
Part No.
Item
AQ3A1-C1-
ZT5VDC
AQ3A1-C2-
ZT5VDC
AQ3A1-C1-
ZT12VDC
AQ3A1-C2-
ZT12VDC
AQ3A1-C1-
ZT24VDC
AQ3A1-C2-
ZT24VDC
AQ3A2-C1-
ZT5VDC
AQ3A2-C2-
ZT5VDC
AQ3A2-C1-
ZT12VDC
AQ3A2-C2-
ZT12VDC
AQ3A2-C1-
ZT24VDC
AQ3A2-C2-
ZT24VDC
Remarks
Input
side
Control voltage
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
The parenthesized values
represent the allowable
voltage ranges
Input impedance
Approx. 0.18 k
Approx. 0.55 k Approx. 1.4 k Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k
Drop-out voltage
min. 0.5 V
min. 1.2 V
min. 2.4 V
min. 0.5 V
min. 1.2 V
min. 2.4 V
Load
side
Max. load current
3 A*1
At ambient temperature of
30
°C or less
Load voltage
75 to 125 V AC
75 to 250 V AC
Frequency
45 to 65 Hz
Repetitive peak
OFF voltage
400 V
600 V
Non-repetitive
surge current
80 A*2
In one cycle at 60 Hz
Max. “OFF-state”
leakage current
2.5 mA/100 V applied
5 mA/200 V applied
at 60 Hz
Max. “ON-state”
voltage drop
1.6 V
at max. carrying current
Min. load current
25 mA*3
50 mA*3
OFF state dV/dt
50 V/
s
At ambient temperature of
80
°C
Part No.
Item
AQ2A1-C1-
T5VDC
AQ2A1-C2-
T5VDC
AQ2A1-C1-
T12VDC
AQ2A1-C2-
T12VDC
AQ2A1-C1-
T24VDC
AQ2A1-C2-
T24VDC
AQ2A2-C1-
T5VDC
AQ2A2-C2-
T5VDC
AQ2A2-C1-
T12VDC
AQ2A2-C2-
T12VDC
AQ2A2-C1-
T24VDC
AQ2A2-C2-
T24VDC
Remarks
Input
side
Control voltage
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
(9.6 to 14.4V)
24 V DC
(21.6 to 26.4V)
The parenthesized values
represent the allowable
voltage ranges
Input impedance
Approx. 0.3 k
Approx. 0.8 k
Approx. 1.8 k
Approx. 0.3 k
Approx. 0.8 k
Approx. 1.8 k
Drop-out voltage
min. 0.5 V
min. 1.2 V
min. 2.4 V
min. 0.5 V
min. 1.2 V
min. 2.4 V
Load
side
Max. load current
2 A*1
At ambient temperature of
30
°C or less
Load voltage
75 to 125 V AC
75 to 250 V AC
Frequency
45 to 65 Hz
Repetitive peak
OFF voltage
400 V
600 V
Non-repetitive
surge current
30 A*2
In one cycle at 60 Hz
Max. “OFF-state”
leakage current
2.5 mA/100 V applied
5 mA/200 V applied
at 60 Hz
Max. “ON-state”
voltage drop
1.6 V
at max. carrying current
Min. load current
25 mA*3
50 mA*3
OFF state dV/dt
50 V/
s
At ambient temperature of
80
°C
All Rights Reserved C
OPYRIGHT Panasonic Electric Works Co., Ltd.