RA RELAYS
(ARA)
1.0GHz 2 Form C RELAY
9.7
.382
5.9
.232
14.70
.579
mm inch
FEATURES
1. High frequency characteristics
(Impedance 50
, ~1.0GHz)
Insertion loss; Max. 0.3dB
Isolation; Min. 20dB
(Between open contacts)
Min. 30dB
(Between contact sets)
V.S.W.R.; Max. 1.2
2. Surface mount terminal
This relay is a surface-mounted model
with excellent high-frequency properties.
In addition, it can use a microstrip line in
the base circuit design which spares the
labor of machining the base.
3. Low prole small type
9.7(W)
×14.7(L)×5.9(H) mm
.382(W)
×.579(L)×.232(H) inch
4. High sensitivity: 140 mW nominal
operating power
5. High contact reliability
Electrical life: Min. 107 (10mA 10V DC)
TYPICAL APPLICATIONS
Measurement instruments
Oscilloscope attenuator circuit
SPECIFICATIONS
Contact
Characteristics
Remarks
* Specications will vary with foreign standards certication ratings.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
*3 Nominal operating voltage applied to the coil, excluding contact bounce time.
*4 By resistive method, nominal voltage applied to the coil: 3W contact carrying
power: at 1.0GHz, Impedance 50
, V.S.W.R. Max.1.2
*5 Half-wave pulse of sine wave: 11ms, detection time: 10
s.
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10
s
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
Arrangement
2 Form C
Contact material
Gold-clad silver alloy
Initial contact resistance
Max. 75m
Rating
Contact rating (resistive)
10mA 10 V DC
1A 30 V DC
Contact carrying power
Max. 3W (at 1.0GHz,
impedance 50
,
V.S.W.R. max.1.2)
Max. switching voltage
30 V DC
Max. switching current
1A
High frequency
characteristics
(~1GHz,
Impedance
50
)
Isolation
Between open
contacts
Min. 20dB
Between
contact sets
Min. 30dB
Insertion loss
Max. 0.3dB
V.S.W.R.
Max. 1.2
Input power
Max. 3W (at 1.0GHz,
impedance 50
,
V.S.W.R. max.1.2)
Nominal
operating
power
Single side stable
140mW (1.5 to 12V)
200mW (24V)
300mW (48V)
1 coil latching
70 mW (1.5 to 12V)
100mW (24V)
2 coil latching
140mW (1.5 to 12V)
200mW (24V)
Expected life
(min.
operation)
Mechanical (at 180 cpm)
108
Electrical
(at 20 cpm)
10mA 10 V DC
(resistive load)
107
1A 30 V DC
(resistive load)
105
Initial insulation resistance *1
Min. 100 M
(at 500 V DC)
Initial
breakdown
voltage *2
Between open contacts
750 Vrms for 1 min.
Between contact sets
1,000 Vrms for 1 min.
Between contact and coil
1,000 Vrms for 1 min.
Between contact and earth
terminal
1,000 Vrms for 1 min.
Operate time [Set time] *3 (at 20°C)
Max. 4ms (Approx. 2ms)
[Max. 4ms (Approx. 2ms)]
Release time (without diode)
[Reset time] *3 (at 20°C)
Max. 4ms (Approx. 1ms)
[Max. 4ms (Approx. 2ms)]
Temperature rise (at 20°C) *4
Max. 60°C
Shock resistance
Functional *5
Min. 500 m/s2
Destructive *6
Min. 1,000 m/s2
Vibration resistance
Functional *7
10 to 55 Hz at double
amplitude of 3mm
Destructive
10 to 55 Hz at double
amplitude of 5mm
Conditions for operation,
transport and storage *8
(Not freezing and
condensing at low
temperature)
Ambient temp
–40°C to +85°C
–40°F to +185°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 2g .07oz