参数资料
型号: ARJ22A24
厂商: Panasonic Electric Works
文件页数: 5/5页
文件大小: 0K
描述: RELAY RF DPDT 300MA 24V
其它有关文件: Standards Chart
标准包装: 50
系列: ARJ
继电器类型: RF
线圈类型: 锁存,双线圈
线圈电流: 6.3mA
线圈电压: 24VDC
触点形式: DPDT(2 C 型)
触点额定值(电流): 300mA
切换电压: 30VDC - 最小值
关闭电压(最大): 18 VDC
安装类型: 表面贴装
端接类型: 鸥翼型
包装: 管件
触点材料: 镀金
操作时间: 5ms
释放时间: 5ms
线圈功率: 150 mW
线圈电阻: 3.84 千欧
工作温度: -30°C ~ 70°C

RJ (ARJ)
8. Measuring method (Impedance 50 ? )
<Standard PC board terminal>
? When used for AC load-operating and
1
2
the operating phase is synchronous.
78 -0.4
16 dia
dia .
di ia.
0. 24
4- -.0
Network B
analyzer A
R
B S parameter
A test set
R
PORT2
1
2
78
-.0 0
.
8.35
.329
4
a.
60 d
1.00
.039
Rocking and fusing can easily occur due
to contact shifting.
? High-frequency load-operating
When high-frequency opening and
di ia.
0. 28
6- -.0
HP 8510C HP 8515A
RF RF
OUT IN
Connector
No. Product name
1 HP 85131-60013
2 HP 83059
PORT1
Contents
3.5 mm testport,
Extension cable
3.5 mm coaxial
adaptor
7.62
.300
3.81
6
.150 a.
70 d
0.90
.035
12.70
.500
17.00
.669
6-1.86
6-.073
0.40
.016
0.40
.016
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO 3 is formed. This
can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(Step 1) Calibrate the test system with
HP calibration kit [HP85052B]
(Step 2) After calibration, connect the
20.00 6.62
.787 .261
6.72
.265
(2) Lower the operating frequency
(3) Lower the ambient humidity
2) Use the relay within speci?cations
D.U.T. board and measure.
Connect 50 ? terminals on
connectors other than those for
measurement.
Notes:
1. All bottom surface of the base should be touched
closely or soldered with PC board ground.
2. 4 ribs should be soldered with PC board ground.
0.50
.020
<Calibration board>
8.89
.350
11.70
.461
30.00
1.181
0.50
.020
such as coil rating, contact rating and on/
off service life. If used beyond limits, the
relay may overheat, generate smoke or
catch ?re.
3) Be careful not to drop the relay. If
accidentally dropped, carefully check its
appearance and characteristics before
Measuring board
1) Dimensions
14.5
.571
use.
4) Be careful to wire the relay correctly.
<Surface mount terminal>
17.00
.669
6-1.76
6-.069
0.80
.031
0.40
.016
0.40
.016
10.0
.394
0.40 or 0.50
.016 or .020
1.76 or 1.86
.069 or .073
Otherwise, malfunction, overheat, ?re or
other trouble may occur.
5) If a relay stays on in a circuit for many
months or years at a time without being
activated, circuit design should be
reviewed so that the relay can remain
2) Material: Glass PTFE double-sided
non-excited. A coil that receives current
7.07
.278
2.81
.111
7.22
.284
through hole PC board R-4737
(Panasonic Corporation)
3) Board thickness: t = 0.8 mm
4) Copper plating: 18 μ m
all the time heats, which degrades
insulation earlier than expected. A
latching type relay is recommended for
such circuits.
h h ia.
Thr -0.40 dia.
8 6 -. 016
20.00
.787
1.00
.039
0.40
.016
8.89
.350
12.04
.474
8.35
.329
0.40
.016
oug d
86
ole
? Connector (SMA type receptacle)
Product name: R125 510 (RADIALL)
Insertion loss compensation
The insertion loss of relay itself is given
by subtracting the insertion loss of short-
circuit the Com and the NC (or NO).
(signal path and two connectors)
9. Others
1) The switching lifetime is de?ned under
6) The latching type relay is shipped in
the reset position. But jolts during
transport or impacts during installation
can change the reset position. It is,
therefore, advisable to build a circuit in
which the relay can be initialized (set and
reset) just after turning on the power.
7) If silicone materials (e.g., silicone
rubbers, silicone oils, silicone coating
the standard test condition speci?ed in
agents, silicone sealers) are used in the
30.00
1.181
the JIS* C 5442-1996 standard
(temperature 15 to 35 ° C 59 to 95 ° F ,
humidity 25 to 75%). Check this with the
real device as it is affected by coil driving
circuit, load type, activation frequency,
activation phase, ambient conditions and
other factors.
Also, be especially careful of loads such
as those listed below.
vicinity of the relay, the gas emitted from
the silicone may adhere to the contacts of
the relay during opening and closing and
lead to improper contact. If this is the
case, use a material other than silicone.
8) We recommend latching type when
using in applications which involve
lengthy duty cycles.
* Japanese Industrial Standards
For general cautions for use, please
refer to the “General Application
Guidelines”.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB105E 201202-T
相关PDF资料
PDF描述
ARN12A24 RELAY RF SPDT 24V
ARS14Y4H RELAY RF SPDT 500MA 4.5V
ARX124H RELAY RF SPDT 500MA 4.5V
ARXP104H RELAY RF SPDT 500MA 4.5V
AS-5042-A SLIDE FULL EXTENSION 20" PAIR
相关代理商/技术参数
参数描述
ARJ22A24J 制造商:Panasonic Electric Works 功能描述:
ARJ22A24X 制造商:NAIS 制造商全称:Nais(Matsushita Electric Works) 功能描述:SMD RELAYS WITH 8GHz CAPABILITIES
ARJ22A24Z 制造商:NAIS 制造商全称:Nais(Matsushita Electric Works) 功能描述:SMD RELAYS WITH 8GHz CAPABILITIES
ARJ22A4H 功能描述:高频/射频继电器 5GHZ DPDT 4.5VDC 2 COIL LATCH SMD RoHS:否 制造商:Omron Electronics 触点形式:2 Form C (DPDT-BM) 触点电流额定值: 线圈电压:5 VDC 线圈类型:Non-Latching 频率: 功耗:100 mW 端接类型:Solder Terminal 绝缘:20 dB to 30 dB at 1 GHz 介入损耗:0.2 dB at 1 GHz
ARJ22A4HJ 制造商:Panasonic Electric Works 功能描述: