参数资料
型号: ARN12A4H
厂商: Panasonic Electric Works
文件页数: 6/6页
文件大小: 0K
描述: RELAY RF SPDT 4.5V
标准包装: 50
系列: ARN
继电器类型: RF
线圈类型: 锁存,双线圈
线圈电流: 88.9mA
线圈电压: 4.5VDC
触点形式: SPDT(1 C 型)
关闭电压(最大): 3.38 VDC
特点: 密封式 - 焊剂防护
安装类型: 表面贴装
端接类型: 鸥翼型
包装: 托盘
触点材料: 镀金
操作时间: 5ms
释放时间: 5ms
线圈功率: 400 mW
线圈电阻: 50.6 欧姆
工作温度: -40°C ~ 85°C

RN (ARN)
9. Measuring method of high frequency characteristics
(Impedance 50 ? )
10. Others
1) The switching lifetime is de?ned under the standard test
Network
analyzer
1
PORT2
2
condition speci?ed in the JIS* C 5442 standard (temperature
15 to 35 ° C 59 to 95 ° F , humidity 25 to 75%RH). Check this with
the real device as it is affected by coil driving circuit, load type,
activation frequency, activation phase, ambient conditions and
Agilent
Te c h n o l o g i e s
E8363B
1
2
other factors. *JIS: Japanese Industrial Standards
Also, be especially careful of loads such as those listed below.
PORT1
Connect connectors 1 and 2 respectively to PORT 1 and
PORT 2. Perform calibration using the 3.5 mm calibration kit
(HP85052B).
? When used for AC load-operating and the operating phase is
synchronous, rocking and fusing can easily occur due
to contact shifting.
? When high-frequency opening and closing of the relay is
performed with a load that causes arcs at the contacts, nitrogen
No.
1
2
Product name
Agilent
85130-60011
SUHNER
SUCOFLEX104
Contents
Adapter
2.4mm-3.5mm female
.095inch-.138inch female
Cable
3.5mm-3.5mm male
.138inch-.138inch male
and oxygen in the air is fused by the arc energy and HNO 3 is
formed. This can corrode metal materials.
Three countermeasures for these are listed here.
(1) Incorporate an arc-extinguishing circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
After calibration, connect the D.U.T. board and measure.
However, connectors other than those for measurement should
be connected with a 50 ? termination resistor.
2) Use the relay within speci?cations such as coil rating, contact
rating and on/off service life. If used beyond limits, the relay may
overheat, generate smoke or catch ?re.
D.U.T. board
Dimensions (mm inch )
3) Be careful not to drop the relay. If accidentally dropped,
28.00
1.102
22.00
.866
8.89
.350
7.00
.276
1.80
.071
2.80
.110
12.00
.472
22.00
.866
2.80
.110
1.80
.071
15.50
.610
carefully check its appearance and characteristics before use.
4) Be careful to wire the relay correctly. Otherwise, malfunction,
overheat, ?re or other trouble may occur.
5) If a relay stays on in a circuit for many months or years at a
time without being activated, circuit design should be reviewed
so that the relay can remain non-excited. A coil that receives
current all the time heats, which degrades insulation earlier than
expected. A latching type relay is recommended for such
circuits.
6) To ensure accurate operation of the latching type amidst
surrounding temperature changes and other factors that might
affect the set and reset pulse times, we recommend a coil
impress set and reset pulse width of at least 30 ms at
Calibration board
Material: Glass PTFE (double-sided, through hole PC board)
R-4737 (Panasonic Corporation)
Board thickness: t = 0.8 mm .031 inch
Copper plating thickness: 18 μ m
Connector (SMA type)
Product name: 01K1808-00 (Waka Manufacturing Co., Ltd.)
Insertion loss compensation: The insertion loss of relay itself is
given by subtracting the insertion loss of calibration board.
the rated operation voltage.
7) The latching type relay is shipped in the reset position. But
jolts during transport or impacts during installation can change
the reset position. It is, therefore, advisable to build a circuit in
which the relay can be initialized (set and reset) just after turning
on the power.
8) If silicone materials (e.g., silicone rubbers, silicone oils,
silicone coating agents, silicone sealers) are used in the vicinity
of the relay, the gas emitted from the silicone may adhere to the
contacts of the relay during opening and closing and lead to
improper contact. If this is the case, use a material other than
silicone.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB71E 201202-T
相关PDF资料
PDF描述
ARN30A24 RELAY RF SPDT 24V
ARN10A24 RELAY RF SPDT 24V
OSTYK31613030 CONN BARRIER STRIP 13CIRC 7.62MM
431715-06-0 TERM BARRIER 6CIRC SGL ROW .4375
431710-06-0 TERM BARRIER 6CIRC SGL ROW .4375
相关代理商/技术参数
参数描述
ARN12A4HX 功能描述:高频/射频继电器 RN Relay 1 Form C Std, 4.5VDC, 88.9mA RoHS:否 制造商:Omron Electronics 触点形式:2 Form C (DPDT-BM) 触点电流额定值: 线圈电压:5 VDC 线圈类型:Non-Latching 频率: 功耗:100 mW 端接类型:Solder Terminal 绝缘:20 dB to 30 dB at 1 GHz 介入损耗:0.2 dB at 1 GHz
ARN12A4HZ 功能描述:高频/射频继电器 RN Relay 1 Form C Std, 4.5VDC, 88.9mA RoHS:否 制造商:Omron Electronics 触点形式:2 Form C (DPDT-BM) 触点电流额定值: 线圈电压:5 VDC 线圈类型:Non-Latching 频率: 功耗:100 mW 端接类型:Solder Terminal 绝缘:20 dB to 30 dB at 1 GHz 介入损耗:0.2 dB at 1 GHz
ARN2-0101-00.11.00.20 制造商:IDEC CORPORATION 功能描述:2 Pos Monolever
ARN2-0101-00.20.00.20 制造商:IDEC CORPORATION 功能描述:2pos Monolever
ARN2-0102-00.11.00.11 制造商:IDEC Corporation 功能描述:2POS Monolever