参数资料
型号: CAT34TS02VP2GT4A
厂商: ON Semiconductor
文件页数: 13/21页
文件大小: 194K
描述: IC TEMP SENSOR 2K MEMORY 8TDFN
标准包装: 1
功能: 温度监控系统(传感器)
传感器类型: 内部
感应温度: -20°C ~ 125°C
精确度: ±3°C
拓扑: ADC,比较器,寄存器库
输出类型: 2 线串行,I²C?/SMBUS?
输出警报:
输出风扇:
电源电压: 3 V ~ 3.6 V
工作温度: -20°C ~ 125°C
安装类型: 表面贴装
封装/外壳: 8-WFDFN 裸露焊盘
供应商设备封装: 8-TDFN(2x3)
包装: 标准包装
其它名称: CAT34TS02VP2GT4AOSDKR
CAT34TS02
http://onsemi.com
13
Temperature Sensor Operation
The TS component in the CAT34TS02 combines a
Proportional to Absolute Temperature (PTAT) sensor with
a SD modulator, yielding a 12 bit plus sign digital
temperature representation.
The TS runs on an internal clock, and starts a new
conversion cycle at least every 100 ms. The result of the
most recent conversion is stored in the Temperature Data
Register (TDR),  and  remains  there  following  a  TS
ShutDown. Reading from the TDR does not interfere with
the conversion cycle.
The value stored in the TDR is compared against limits
stored in the High Limit Register (HLR), the Low Limit
Register (LLR)  and/or  Critical Temperature Register
(CTR). If the measured value is outside the alarm limits or
above the critical limit, then the EVENT
  pin may be
asserted. The EVENT
 output function is programmable, via
the Configuration Register for interrupt mode, comparator
mode and polarity.
The temperature limit registers can be Read or Written by
the host, via the serial interface. At poweron, all the
(writable) internal registers default to 0x0000, and should
therefore be initialized by the host to the desired values. The
EVENT
  output starts out disabled (corresponding to
polarity active low); thus preventing irrelevant event bus
activity before the limit registers are initialized. While the
TS is enabled (not shutdown), event conditions are
normally generated by a change in measured temperature as
recorded in the TDR, but limit changes can also trigger
events as soon as the new limit creates an event condition,
i.e. asynchronously with the temperature sampling activity.
In order to minimize the thermal resistance between
sensor and PCB, it is recommended that the exposed
backside die attach pad (DAP) be soldered to the PCB
ground plane.
Registers
The CAT34TS02 contains eight 16bit wide registers
allocated to TS functions, as shown in Table 9. Upon
powerup, the internal address counter points to the
capability register.
Capability Register (User Read Only)
This register lists the capabilities of the TS, as detailed in
the corresponding bit map.
Configuration Register (Read/Write)
This register controls the various operating modes of the
TS, as detailed in the corresponding bit map.
Temperature Trip Point Registers (Read/Write)
The CAT34TS02 features 3 temperature limit registers,
the HLR, LLR and CLR mentioned earlier. The
temperature value recorded in the TDR is compared to the
various limit values, and the result is used to activate the
EVENT
 pin. To avoid undesirable EVENT
 pin activity, this
pin is automatically disabled at powerup to allow the host
to initialize the limit registers and the converter to complete
the first conversion cycle under nominal supply conditions.
Data format is twos complement with the LSB representing
0.25癈, as detailed in the corresponding bit maps.
Temperature Data Register (User Read Only)
This register stores the measured temperature, as well as
trip status information. B15, B14, and B13 are the trip status
bits, representing the relationship between measured
temperature and the 3 limit values; these bits are not affected
by EVENT status or by Configuration register settings
regarding   EVENT
   pin.   Measured   temperature   is
represented by bits B12 to B0. Data format is twos
complement, where B12 represents the sign, B11 represents
128癈, etc. and B0 represents 0.0625癈.
Manufacturer ID Register (Read Only)
The manufacturer ID assigned by the PCISIG trade
organization to the CAT34TS02 device is fixed at 0x1B09.
Device ID and Revision Register (Read Only)
This register contains manufacturer specific device ID
and device revision information.
Table 9. THE TS REGISTERS
Register Address
Register Name
PowerOn Default
Read/Write
0x00
Capability Register
0x007F
Read
0x01
Configuration Register
0x0000
Read/Write
0x02
High Limit Register
0x0000
Read/Write
0x03
Low Limit Register
0x0000
Read/Write
0x04
Critical Limit Register
0x0000
Read/Write
0x05
Temperature Data Register
Undefined
Read
0x06
Manufacturer ID Register
0x1B09
Read
0x07
Device ID/Revision Register
Rev. B
0x0813
Read
Rev. C
0x0A00
相关PDF资料
PDF描述
CAT6095VP2-GT4 IC TEMP SENSOR STAND ALONE 8TDFN
DS1621S+ IC THERMOMETER/STAT DIG 8-SOIC
DS1624S+T&R IC THERM/EEPROM DIG 256BYT 8SOIC
DS1626S+ IC THERMOMETER/STAT DIG 8-SOIC
DS1629S+T&R IC THERM/RTC/CALENDAR DIG 8-SOIC
相关代理商/技术参数
参数描述
CAT34TS02VP2GT4B 功能描述:板上安装温度传感器 TEMP SENSOR WITH MEMORY RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
CAT34TS02VP2GT4C 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
CAT34TS02VP2IGT4 功能描述:板上安装温度传感器 Temp Sensor w/memory RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
CAT34TS04 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Digital Output Temperature Sensor with On-board SPD EEPROM
CAT34TS04EVP2GT4A 功能描述:TEMPERATURE SENSOR WITH 制造商:on semiconductor 系列:- 零件状态:在售 传感器类型:数字,本地 检测温度 - 本地:-20°C ~ 125°C 检测温度 - 远程:- 输出类型:I2C/SMBus 电压 - 电源:2.2 V ~ 5.5 V 分辨率:12 b 特性:输出开关,可编程极限,可编程分辨率,待机模式 精度 - 最高(最低):±1°C(±3°C) 测试条件:75°C ~ 95°C(-20°C ~ 125°C) 工作温度:-45°C ~ 130°C 安装类型:表面贴装 标准包装:4,000