Data Sheet
World Modem NET
Page 21 of 64
2005 Copeland Communications, Inc.
World Modem NET Datasheet Rev 1.0
Basic AT Command Set (Command Defaults in Bold) (Continued)
Command
Action
+IFC Options
Specifies the flow control to be implemented.
+IFC = A
A
Specifies the flow control method used by the host to control data from the modem.
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remot modem.
2 Hardware flow control (RTS).
B
Specifies the flow control method used by the modem to control data from the host.
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remot modem.
+IFC = A,B
2 Hardware flow control (CTS).
+ITF Options
Transmit flow control threshold.
+ITF = A
A
Threshold above which the modem will generate a flow off signal.
+ITF = A,B
< 0 to 511> bytes
B
Threshold below which the modem will generate a flow on signal
< 0 to 511> bytes
C
Polling interval for <EM><BNUM> indicator
+ITF = A,B,C
0 to 300 in 10 msec units.
Modulation reporting control.
X
Mode
0
Disabled
1
Enabled
If enabled, the intermediate result code is transmitted at the point during connect negotiation. The
format of this result code is asw follows:
+MCR: <carrier> e.g. +MCR: V32B
+MR = X
+MRR: <rate> e.g. +MRR: 14400
+MS Options
Modulation Selection.
+MS = A
A
Preferred modem carrier
+MS = A,B
V21
ITU-T V.21
+MS = A,B,C
V22
ITU-T V.22
+MS = A,B,C,D
V.22B
ITU-T V.22bis
+MS = A,B,C,D,E
V32
ITU-T V.32 (default for CC-14.4K2)
V.32B
ITU-T V.32bis
V34
ITU-T V.34 (default for CC-33K2)
V90
ITU-T V.90 (default for CC-56K2)
B
Automatic modulation negotiation
0
Disabled
1
Enabled
C,D Min rate/Min rx rate are optional numeric values that specify the lowest value at which the
DCE ma establish a connection. If unspecified (set to zero), the are determined by the carrier and
automode settings.
+MS =
A,B,C,D,E,F
E,F Max rate/Max rx rate are optional numeric values which specify the highest values which
specify the highest value at which the DCE may establish a connection. If unspecified (set to 0),
they are determined by the carrier and automode settings.
相关PDF资料
PDF描述
CC-93K2N-CS5 MODEM 56KBAUD SERIAL V.92 5V
CC-56K2N-CS5 MODEM 56KBAUD SERIAL 5V
CC-2404K2N-CS5 MODEM 2400BAUD SERIAL 5V
SI3015-BS IC ISOMODEM LINE-SIDE DAA 16SOIC
PIC16C54T-XTE/SO IC MCU OTP 512X12 18SOIC
相关代理商/技术参数
参数描述
CC-56K2N-CS5 功能描述:MODEM 56KBAUD SERIAL 5V RoHS:是 类别:集成电路 (IC) >> 接口 - 调制解调器 - IC 和模块 系列:- 标准包装:25 系列:- 数据格式:V.21,V.22,V.23,V.29,V.32,V.34,V.90,V.92,Bell 103,Bell 212A 波特率:33.6k 电源电压:3.3V 安装类型:- 封装/外壳:- 供应商设备封装:- 包装:托盘 配用:591-1013-ND - KIT DEV SOCKETMODEM PARALLEL591-1009-ND - KIT DEV SRL SOCKETMODEM UNIVERSL 其它名称:MT5656SMI-P-V-34.R2-SPMT5656SMI-P-V-34.R2-SP-NDQ4711574
CC57434 制造商: 功能描述: 制造商:undefined 功能描述:
CC5751-000 制造商:TE Connectivity 功能描述:TWTMS-1/8-NO.11-1-CS5004 - Bulk
CC5872-000 制造商:TE Connectivity 功能描述:100A0111-18-54-CA
CC58C-05 制造商:L-com Inc 功能描述:CABLE ASSEMBLY RG58C BNC M/M 制造商:L-com Inc 功能描述:CABLE ASSEMBLY, RG58C, BNC M/M, 0.5FT 制造商:L-com Inc 功能描述:CABLE ASSEMBLY, RG58C, BNC M/M, 0.5FT; Coaxial Cable Type:RG58C; Impedance:50ohm; Cable Length - Imperial:6"; Cable Length - Metric:150mm; Connector Type A:BNC Straight Plug; Connector Type B:BNC Straight Plug; Jacket Color:Black ;RoHS Compliant: Yes