参数资料
型号: CUB30000
厂商: Red Lion Controls
文件页数: 2/2页
文件大小: 0K
描述: COUNTER GEN PURPOSE FOR CUB30000
标准包装: 5
系列: CUB3
计数速率: 100Hz
数字/字母数: 6
输入类型: 开关外壳或晶体管开关
电源电压: 3V
显示器类型: LCD 无背光
产品目录页面: 2853 (CN2011-ZH PDF)
其它名称: CUB III
CUB-30-00
CUB-30-00/A
CUB-30-000/A
CUB3
RLC03
DIMENSIONS In inches (mm) , INSTALLATION & BATTERY INSERTION
Installation Environment
The unit should be installed in a location that does not exceed the maximum
operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.
PANEL CUT-OUT
1" x 2" or 25 MM x 50 MM
PANEL THICKNESS
0.05" to 0.125"
The bezel should be cleaned only with a soft cloth and neutral soap product.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate
the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the
keypad of the unit.
TO REMOVE REAR BATTERY COVER
INSERT BLADE OF SMALL SCREWDRIVER
IN R.H. OPENING AND SWING HANDLE
SLIGHTLY TO THE RIGHT TO DEFLECT
INTERNAL CLASP. RIGHT HAND SIDE OF
COVER WILL NOW SWING OUT.
EMC INSTALLATION GUIDELINES
Although this unit is designed with a high degree of immunity to
ElectroMagnetic Interference (EMI), proper installation and wiring methods
must be followed to ensure compatibility in each application. The type of the
electrical noise, source or coupling method into the unit may be different for
various installations. Listed below are some additional EMC guidelines for
successful installation in an industrial environment.
1. Use shielded (screened) cables for all Signal and Control inputs. The shield
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in
order of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
ground (protective earth).
b. Connect the shield to earth ground at both ends of the cable, usually when
the noise source frequency is above 1 MHz.
c. Connect the shield to common of the unit and leave the other end of the
shield unconnected and insulated from earth ground.
2. Never run Signal or Control cables in the same conduit or raceway with AC
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run in metal conduit that is properly
4. In extremely high EMI environments, the use of external EMI suppression
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
The following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables :
Fair-Rite # 0443167251 (RLC #FCOR0000)
TDK # ZCAT3035-1330A
Steward #28B2029-0A0
5. Long cable runs are more susceptible to EMI pickup than short cable runs.
Therefore, keep cable runs as short as possible.
ELECTRICAL CONNECTIONS & COUNT INPUTS
The CUB 3s can be supplied with count input signals from mechanical
switch contacts or solid-state switches (NPN or PNP transistors) as shown in
the diagrams below. Reed switches, mercury-wetted contacts, snap-action limit
switches, and silver alloy contacts with wiping action are usually satisfactory
choices for mechanical switch input. Heavy “ clapper-type” contacts such as
used in contactors or large machine tool relays, tungsten contacts, or brush type
contacts are not recommended as count input devices.
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
3. Signal or Control cables within an enclosure should be routed as far away as
possible from contactors, control relays, transformers, and other noisy
components.
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate company
numbers listed.
Red Lion Controls
Red Lion Controls
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Printerweg 10
NL - 3821 AD Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
India
54, Vishvas Tenement
GST Road, New Ranip,
Ahmedabad-382480 Gujarat, India
Tel +91 987 954 0503
Fax +91 79 275 31 350
China
Unit 101, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113-3688
Fax +86 21 6113-3683
相关PDF资料
PDF描述
CUB3LR00 CNTR W/BATT CUB3L000 REM SENSOR
CUB3T330 MODULE LCD TIMER .1 MIN W/ RESET
CUB4L800 8-DIGIT COUNTER, REFLECTIVE
CUB5RLY0 BOARD RELAY PLUG-IN FOR CUB5
CUB5TB00 TIMER & CYCLE COUNTER W/BKLT
相关代理商/技术参数
参数描述
CUB3A-1 制造商:IMO Precision Controls Ltd 功能描述:INVERTER 1 PHASE 0.55KW 制造商:IMO Precision Controls Ltd 功能描述:AC MOTOR DRIVER; Supply Voltage Min:200VAC; Supply Voltage Max:240VAC; No. of Phases:Single; Power Rating:0.55kW; Output Voltage Max:230V; External Depth:97mm; Frequency Range:0.1 to 400Hz; Input Current:5.4A; Output Current:3A ;RoHS Compliant: Yes
CUB3A-1 制造商:IMO Precision Controls Ltd 功能描述:INDICATOR M/BLOCK LED 230AC RE
CUB3A7-4 制造商:IMO Precision Controls Ltd 功能描述:INVERTER 3 PHASE 1.5KW 制造商:IMO Precision Controls Ltd 功能描述:AC MOTOR DRIVER; Supply Voltage Min:380VAC; Supply Voltage Max:480VAC; No. of Phases:Three; Power Rating:1.5kW; Output Voltage Max:415V; External Depth:141mm; Frequency Range:0.1 to 400Hz; Input Current:5.9A; Output Current:3.7A ;RoHS Compliant: Yes
CUB3K000 制造商:Red Lion 功能描述:
CUB3L000 制造商:Red Lion Controls 功能描述:Counter; Miniature Electronic; 3 V; Digital; LCD; 6; 0 to 999999; Snap-In