参数资料
型号: CUB3LR00
厂商: Red Lion Controls
文件页数: 2/2页
文件大小: 0K
描述: CNTR W/BATT CUB3L000 REM SENSOR
标准包装: 1
系列: CUB3
计数速率: 100Hz
数字/字母数: 6
输入类型: 开关外壳或晶体管开关
电源电压: 不需要(包括电池)
显示器类型: LCD 无背光
其它名称: CUB3LR000
CUB3LR000-ND
Q1164751
DIMENSIONS In inches (mm) & INSTALLATION
2.09 (53)
BEZEL
1.94 (49.3)
BODY
0.150 (3.8) BEZEL
PROTRUSION FROM
PANEL FRONT
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the
maximum operating temperature and provides good air circulation. Placing
the unit near devices that generate excessive heat should be avoided.
The bezel should be cleaned only with a soft cloth and neutral soap
product. Do NOT use solvents. Continuous exposure to direct sunlight may
accelerate the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate
the keypad of the unit.
1.10 (28)
BEZEL
0.95 (24.2)
BODY
1.72 (43.7)
BODY DEPTH
(MAX) BEHIND BEZEL
PANEL CLASP
(ONE ON
EACH SIDE)
COUNT INPUT
LEADS 22GA
12 LONG (WHT)
COMMON
(BLK)
PANEL CUT-OUT
1" x 2" or 25 mm x 50 mm
PANEL THICKNESS
0.05" to 0.125"
COMMON
STRAIN
RELIEF
COUNT
INPUT
LEADS
Count and Reset Inputs
(+)CNT. IN (WHT)
EMCCOMPLIANCEINSTALLATION
This unit complies with the Electromagnetic Compatibility (EMC) standards
listed in the specifications. Compliance to the EMC standards was demonstrated
by means of a test set-up using the following installation methods:
1. Unit installed in a metal panel mounted to an open aluminum rack connected
to earth ground (protective earth).
2. Shielded (screened) cables for Signal and Control inputs with shield drain
wire connected to earth ground at the mounting panel only.
Multi-conductor Cable Function Used For
Belden #8451 - 2 conductor, #22 AWG twisted
pair w/ foil shield and drain wire
It should be noted that the methods listed above may not be necessary for
every unit installation. For the purpose of EMC testing, the input line on the unit
was connected with 25 feet (8 m) of cable. In extremely high EMI environments,
additional measures may be needed. Cable length, routing and shield termination
are very important and can mean the difference between a successful installation
or a troublesome installation.
ADDITIONAL EMC INSTALLATION GUIDELINES
Although this unit is designed with a high degree of immunity to
ElectroMagnetic Interference (EMI), proper installation and wiring methods
must be followed to ensure compatibility in each application. The type of the
electrical noise, source or coupling method into the unit may be different for
various installations. Listed below are some additional EMC guidelines for
successful installation in an industrial environment.
1. Use shielded (screened) cables for all Signal and Control inputs. The shield
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
ground (protective earth).
b. Connect the shield to earth ground at both ends of the cable, usually when
the noise source frequency is above 1 MHz.
c. Connect the shield to common of the unit and leave the other end of the
shield unconnected and insulated from earth ground.
2. Never run Signal or Control cables in the same conduit or raceway with AC
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
3. Signal or Control cables within an enclosure should be routed as far away as
possible from contactors, control relays, transformers, and other noisy
components.
4. In extremely high EMI environments, the use of external EMI suppression
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
The following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables :
Fair-Rite # 0443167251 (RLC #FCOR0000)
TDK # ZCAT3035-1330A
Steward #28B2029-0A0
5. Long cable runs are more susceptible to EMI pickup than short cable runs.
Therefore, keep cable runs as short as possible.
ELECTRICAL CONNECTIONS &
COUNT INPUTS
The CUB3Ls can be supplied with count input signals from mechanical
switch contacts or solid-state switches (NPN or PNP transistors) as shown
in the diagrams below. Reed switches, mercury-wetted contacts, snap-action
limit switches, and silver alloy contacts with wiping action are usually
satisfactory choices for mechanical switch input. Heavy “ clapper-type”
contacts such as used in contactors or large machine tool relays, tungsten
contacts, or brush type contacts are not recommended as count input devices.
SWITCH NPN O.C. PNP O.C.
CONTACT TRANSISTOR TRANSISTOR
RST.(BLUE)
COUNTER
(-)COMMON(BLK)
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate
company numbers listed.
相关PDF资料
PDF描述
CUB3T330 MODULE LCD TIMER .1 MIN W/ RESET
CUB4L800 8-DIGIT COUNTER, REFLECTIVE
CUB5RLY0 BOARD RELAY PLUG-IN FOR CUB5
CUB5TB00 TIMER & CYCLE COUNTER W/BKLT
CUB7P200 HSPEED LOGIC INPUT CNTR POS
相关代理商/技术参数
参数描述
CUB3R000 制造商:Red Lion Controls 功能描述:COUNTER, MINI W/REMOTE RESET 制造商:Red Lion Controls 功能描述:COUNTER W/REMOTE RESET 制造商:Red Lion Controls 功能描述:CUB3 CNTR W/REMOTE RESET
CUB3T300 功能描述:MODULE LCD TIMER 1 HR W/ RESET RoHS:否 类别:工业控制,仪表 >> 定时器 系列:CUB3 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB3T310 功能描述:MODULE LCD TIMER .1 HR W/ RESET RoHS:否 类别:工业控制,仪表 >> 定时器 系列:CUB3 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB3T320 功能描述:MODULE LCD TIMER .01 HR W/ RESET RoHS:否 类别:工业控制,仪表 >> 定时器 系列:CUB3 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB3T330 功能描述:MODULE LCD TIMER .1 MIN W/ RESET RoHS:否 类别:工业控制,仪表 >> 定时器 系列:CUB3 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992