AC CONTROL
(120Vac)
MODEL NUMBERS
(24Vac)
CXE
240A5 - MS11
DC CONTROL
(5Vdc)
(24Vdc)
OUTPUT SPECIFICATIONS (1)
Operating Voltage (47-63 Hz) [Vrms]
12-280
Load Current Range [Arms]
.06-5
Transient Overvoltage [Vpk]
600
Max. Surge Current, (16.6ms) [Apk]
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.4
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
Max. Off-State Leakage Current @ Rated Voltage [mArms]
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/sec] (2)
500
Max. Turn-On Time (3)
1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Power Factor (Min.) with Max. Load
0.5
INPUT SPECIFICATIONS
(1)
DC CONT R OL
AC CONT R OL (4)
Nominal Voltage
5Vdc
24Vdc
120Vac
24Vac
MODEL NUMBERS
Control Voltage Range
3-15 Vdc
15-32 Vdc
90-140 Vrms
18-36 Vrms
Max. Turn-On Voltage
3.0 Vdc
15.0 Vdc
90.0 Vrms
18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10.0 Vrms
2.0 Vrms
Nominal Input Impedance
300 Ohm
1.0k Ohm
14.1k Ohm
4.2k Ohm
Typical Input Current @ Nominal Voltage
15 mAdc
8 mAdc
10 mArms
5 mArms
G E N E R A L NO T ES
(1) All parameters at 25C unless otherwise specified.
(2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
(3) Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).
SCR Output
Ultra High Surge
Rating
Crydom’s Patented Design
SERIES CX-MS
11.
Rev.
180608
PAGE 1 OF 4
Series CX - MS
11
exceptional steady state current, plus
ultra-high surge ratings.
Models are
available to switch up to 530 Vrms with
AC or DC control, and either zero-cross
or random turn-on ("R") switching ver-
sions.
200
8 CRYDOM Inc, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom
Inc, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202
606030 FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: sales-europe@crydom.com, tech-europe@crydom.com
GERMANY: +49 (0)180 3000 506
5 Amp 240, 480 Vac AC Output
CX
240A5 - MS11
CXE
240D5 - MS11
CX
240D5 - MS11
CXE
240A5 - MS11
CX
240A5 - MS11
CX
240D5 - MS11
CXE
240D5 - MS11
Crydom's family of SPST-NO relays
achieves the highest power switching
capability in a DIN mounted air-cooled
package.
Advanced features include
Input Status LED (DC Control only)
DIN Rail Mount (TS-35)
(4) No input status LED on AC control modules.
CXE
380D5 - MS11
CX
380D5 - MS11
48-530
.06-5
1200
250
1.4
260
0.1
500
0.5
CX
380D5 - MS11 CXE380D5 - MS11