参数资料
型号: DMS-EB2-C
厂商: Murata Power Solutions Inc
文件页数: 2/4页
文件大小: 0K
描述: APPLICATION BRD FOR DMS-20 METER
标准包装: 12
系列: *
产品目录页面: 2856 (CN2011-ZH PDF)
其它名称: 811-1124
DMS-EB2
Multi-Purpose Application Board
for DMS-20PC/LCD Meters
Functional Speci?cations (T A = 25oC)
Input Supply Range
See applicable meter's data sheet
Input Supply Range U1 (LM7805CT) Installed:
A 10μF/35V tantalum capacitor (C2 on schematic) should be installed
with the polarized end next to the + symbol on the DMS-EB2. This is
especially important if the power source is located far from U1.
5. Soldering: DATEL recommends the use of "no-clean" solders when
making modi?cations to the DMS-EB2.
DMS-20PC-X-XS
DMS-20PC-X-XL
+7.5 to +12.6V
+7.5 to +32.0V
DMS-20LCD-X-5
DMS-20LCD-X-5B
Operating and Storage Temperature
See applicable meter's data sheet
Humidity
Dimensions
J1 Connector & Wire Information
Terminal Type
Crimp Tool
Wire Size
+7.5 to +32.0V
+7.5 to +12.6V
0 to 95%, non-condensing
1.25" (31.8mm)L x 0.75" (19.1mm)H
DATEL P/N 39-2099090
DATEL P/N 39-2099000
22 to 26 AWG
APPLICATIONS
As shipped, the DMS-EB2 is con?gured for single-ended operation.
This con?guration is preferred for simple voltage measurements and will
generally cover most standard applications. Figure 1 indicates which
solder gaps are shipped closed from the factory.
Simply solder the board onto the meter (pin 1 to pin 1), connect
the power supply to J1, pin 5 (+V) and the power return to J1, pin 6
(GROUND).
Insulation Diameter
Stripping Length
0.062" (1.57mm) max.
0.100" to 0.125"
(2.54 to 3.17mm)
Pin Function
1 (+) INPUT HI
J1
2 (–) INPUT LO
Ordering Information
3 TEST/HOLD IN
1
2
3
4
5
6
4 TEST/HOLD OUT
DMS-EB2
DMS-BZL3
DMS-BZL4
39-0304000
39-2359625
Application board with mating connector and terminals
DMS-20 bezel assembly
DMS-20 bezel assembly with sealing gasket
LM7805CT (U1), +5V-output, three-terminal regulator
6-position pc-board socket
5 +V (Positive power connection)
6 –V (Ground, negative power return)
Figure 2. J1 Connector Pinout
1.Decimal Point Placement: DATEL ships the DMS-EB2 with all decimal
point solder gaps (SG1, SG2 and SG3) open. To enable a speci?c
TECHNICAL NOTES
1.LCD Backlighting: To backlight a DMS-20LCD meter, connect J1, pin 3
(TEST/HOLD IN) to J1, pin 6 (GND). This allows for external control,
via a switch, of the backlight feature. The switch should be rated for low
voltage operation at 35mA.
2. 9V LCD Meters: DMS-20LCD-X-9 meters cannot be used in a single-
ended con?guration, i.e., with (–) IN LO tied to GND. On these models,
both (–) IN LO and (+) IN HI have to be a minimum of 1.5V above and
1.5V below J1 pins 6 and 5, respectively. To operate from a 9V or 12V
battery with (–) IN LO tied to GND, use a 5V-powered meter (DMS-
20LCD-X-5), install U1 (LM7805CT) and open SG4.
3. Input Resistor Dividers: Always use 1%, or better, metal-?lm resistors
for R1 and R2, and also make sure their power and voltage ratings are
adequate for the given application.
4. Using U1 (LM7805CT): The input power range speci?ed in the Battery
Operation section is rated conservatively assuming a 100mA LED meter
or a 35mA backlit LCD meter. If a non-backlit LCD model or the low-
power LED model is used, the input voltage range can be extended up to
32Vdc.
www.murata-ps.com
decimal point, close its respective solder gap with solder. When
re-assigning decimal places for subsequent applications, remember to
unsolder previously closed solder gaps.
Close SG1 for 1.999 (DP1)
Close SG2 for 19.99 (DP2)
Close SG3 for 199.9 (DP3)
2. Display Test (Not Available on LCD Models) : Tie pin 4 (TEST/HOLD
OUT) to pin 3 (TEST/HOLD IN) to test the display of the DMS-20PC.
Do not leave the meter in the test mode for more than 10 seconds. On
LED meters with the HOLD option, tying pins 3 and 4 together freezes
the display reading.
3. Battery Operation: Open SG4 and install U1 (LM7805CT) with its metal
tab facing to the left as shown in Figure 3. Allowable input power ranges
(J1, pins 5 and 6) are as follows:
DMS-20PC-X-XS +7.5 to +12.6Vdc
DMS-20PC-X-XL +7.5 to +32Vdc
C2 (10μF/35V) can be added to reduce noise. Observe correct polarity.
Refer to Technical Note 4 for more information.
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-EB2.E01 Page 2 of 4
相关PDF资料
PDF描述
DMS-PS1-CM-C MODULE PS 5V 1A CHASSIS-MOUNT
DMT-8-15 XFRMR 115/230V 5V 4A 8VA 3OUT
DMTT-1000 XFRMR MCHN TOOL 120V 24VCT 41.7A
DNR110A CONTROL LIQUID LEVEL DIN 110VAC
DP-241-8-56L XFRMR PWR 115/230V 56VCT 1.8A
相关代理商/技术参数
参数描述
DMS-EB-AC/DC 功能描述:数字面板表 AC Primary Power Application Board RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-EB-AC/DC-C 功能描述:数字面板表 AC Primary Power Application Board RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-EB-C 功能描述:数字面板表 Multipurpose board for DMS-30/40 meters RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-EB-DC/DC 功能描述:数字面板表 DC-DC Converter and Isolation Board RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM