参数资料
型号: DMS-PS1-CM-C
厂商: Murata Power Solutions Inc
文件页数: 4/8页
文件大小: 0K
描述: MODULE PS 5V 1A CHASSIS-MOUNT
标准包装: 5
系列: DMS-PS-CM
产品目录页面: 2856 (CN2011-ZH PDF)
其它名称: 811-1120
DMS-PS-CM Series
High Ef?ciency, AC/DC Instrumentation Power
Supplies with Individually Isolated Outputs
The ac-mains circuit supplying power to DMS-PS-CM supplies must be fused
according to the current rating of the wire gauge used, in accordance with
applicable regulatory codes. The built-in 1ampere line fuse (F1) only protects
the module itself from destructive over currents.
5. AC Mains Connections (TB4): To ensure EMI-compliant operation, all three
ac-supply inputs must be properly connected to TB4. Never operate any DMS-
PS-CM power supply without a ground connection to TB4’s ‘FG’ terminal.
On 120Vac 50/60Hz mains, connect the black or "hot" lead to ‘AC(L)’, the
white or “neutral” lead to ‘AC(N)’, and the supply ground (earth) to ‘FG’ (Frame
Ground). On 220V 50/60Hz ac mains with line and neutral conductor-designa-
tions, connect the line to AC(L), the neutral to AC(N), and the ground to ‘FG’.
6. Connector Torque Ratings: It is extremely important to tighten all input and
output terminal blocks securely. TB4’s screw terminals must be torqued to
4.4 pound-inches (0.5Nm). TB1, TB2, and TB3 must be torqued to 3.6 pound-
inches (0.4Nm). Proper tightening will minimize losses and ensure safe,
reliable operation.
7. ‘Power On’ LED: The Power On LED indicates that the unit has ac-power
applied and its V1 dc-output is operational. However, the power-on LED’s
illumination does not imply nor guarantee that the unit’s dc-outputs are within
their speci?ed accuracy.
8. Output Adjustment: The main output, V1, on all 5, 10, and 16W models is
adjustable by approximately –10% to +15%. V1’s adjustment potentiometer
is accessed via a small hole located next to the Power-On LED. While not
recommended, ?eld adjustment of single-output models can be performed
within the tolerance window noted above. However, keep in mind that the
unit’s maximum output power capability must not be exceeded. For example,
increasing V1’s output voltage by 10% produces a corresponding 10% reduc-
tion in V1’s maximum output current.
On dual-and triple-output units, V1 is factory calibrated with all outputs
simultaneously loaded to 100% of their rated current. On all dual- and
triple output models, adjusting V1 under any condition other than
those just noted (i.e., all outputs loaded to their full rated current) will
2.0% / oC
100
75
50
25
0
adversely affect the operation and stability of auxiliary outputs V2 and
V3. On these models, V1 must be adjusted to within ±2 % of its nominal
value (+5.0V, +12.0V, or +24.0V, depending on model).
9. Temperature Derating (See Figure 3): All DMS-PS-CM supplies are speci-
?ed to operate at their full rated power over the temp range of 0°C to +50°C
in still air (convection cooling) without any thermal derating. For operation
over +50°C in still air, derate the output power linearly by 2.5% per °C down
to 50% rated power at +70°C. To operate the units at full rated power between
+50°C and +70°C, a minimum forced-air?ow of 100 LFM is required. For
operation below 0°C, derate the output power linearly by 2.0% per °C down
to 50% rated power at –25°C.
Unless forced air with the velocity noted above is employed, DMS-PS-CM
supplies should never be mounted upside down (terminal blocks facing
down). Also, always provide suf?cient clearances in order to ensure adequate
air?ow around the supply.
10. V1 Peak Capabilities: DMS-PS-CM power supplies have a maximum
continuous output-current rating that’s speci?ed in the Ordering and Selection
Guide. In addition, each model’s V1 output can intermittently supply 120% of
its continuous rated current for short periods of time if the duty cycle is less
than 10%. Peak current ratings do not apply to the auxiliary outputs V2 or V3.
11. Isolated Outputs: Unlike the majority of competitive ac/dc power supplies,
all dual- and triple-output DMS-PS-CM power supplies feature fully-isolated
outputs. This is an important feature when, for reasons of high common mode
voltages, an instrument’s input circuit must be isolated from the system ground.
All V1 outputs are isolated from the ac mains by a minimum of 3000Vac, while
auxiliary outputs V2 and V3 are isolated from one another by 2000Vdc, and
fromV1 by 1000Vdc. The low noise, double-isolated auxiliaries are ideal for
powering sensitive instrumentation that requires low ac leakage-currents.
All ac/dc and dc/dc power components utilized in the construction of DMS-
PS-CM power supplies are 100% hi-pot tested during their manufacturing pro-
cesses. In addition, after ?nal assembly by MPS, all models are subjected to an
additional hi-pot testing consisting of 1000Vac sequentially applied between the
ac mains input and each output, and between each output and all other outputs.
2.5% / oC
70oC
–25
–10
0
10
15
20
25
30
35
40
45
50
55
60
65
70
75
Figure 3. Temperature Derating
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-PS-CM.B02 Page 4 of 8
相关PDF资料
PDF描述
DMT-8-15 XFRMR 115/230V 5V 4A 8VA 3OUT
DMTT-1000 XFRMR MCHN TOOL 120V 24VCT 41.7A
DNR110A CONTROL LIQUID LEVEL DIN 110VAC
DP-241-8-56L XFRMR PWR 115/230V 56VCT 1.8A
DPC-24-1000 XFRMR PWR 115/230V 24VCT 1.0A
相关代理商/技术参数
参数描述
DMS-PS2-CM 功能描述:线性和开关式电源 5W 5Vdc/0.65A 4.85Vdc/0.2A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
DMS-PS2-CM-C 功能描述:线性和开关式电源 5W High-Eff AC/DC Instrumentation PS RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
DMS-PS3-CM 功能描述:线性和开关式电源 5W 5Vdc/.35A/4.85Vdc /0.2A/4.85Vdc/0.2A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
DMS-PS3-CM-C 功能描述:线性和开关式电源 5W High-Eff AC/DC Instrumentation PS RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
DMS-PS4-CM 功能描述:线性和开关式电源 10W 24Vdc/0.45A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度: