参数资料
型号: DS2181AQN
厂商: Maxim Integrated Products
文件页数: 15/32页
文件大小: 0K
描述: IC TXRX CEPT PRIM RATE IN 44PLCC
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 26
类型: 收发器
驱动器/接收器数: 1/1
规程: CEPT
电源电压: 4.5 V ~ 5.5 V
安装类型: 表面贴装
封装/外壳: 44-LCC(J 形引线)
供应商设备封装: 44-PLCC(16.59x16.59)
包装: 管件
DS2181A
22 of 32
CECR: CRC4 ERROR COUNT REGISTER Figure 21
(MSB)
(LSB)
CRC7
CRC6
CRC5
CRC4
CRC3
CRC2
CRC1
CRC0
SYMBOL
POSITION
NAME AND DESCRIPTION
CRC7
BVCR.7
MSB of CRC4 error count.
CRC0
BVCR.0
LSB of CRC4 error count.
FECR: FRAME ERROR COUNT REGISTER Figure 22
(MSB)
(LSB)
FE7
FE6
FE5
FE4
FE3
FE2
FE1
FE0
SYMBOL
POSITION
NAME AND DESCRIPTION
FE7
FECR.7
MSB of frame error count.
FE0
FECR.0
LSB of frame error count.
ERROR LOGGING
The BVCR, CECR and FECR contain 8-bit binary up counters which increment on individual bipolar
violations, CRC4 code word errors (when CCR.2 = 1), and word errors in the frame alignment signal.
Each counter saturates at 255. Once saturated, each following error occurrence will generate an interrupt
(RIMR.0 = 1) until the register is reprogrammed to a value other than FF (hex). Presetting the registers
allows the user to establish specific error count thresholds; the counter will count up to saturation from
the preset value. The BVCR increments at all times (regardless of sync status), except when HDB3 code
words are received with CCR.4=1. CECR and FECR increments are disabled whenever resync is in
progress (RLOS high).
ALARM OUTPUTS
Alarm conditions are also reported real time at alarm outputs. These outputs can be used with off-chip
logic to complement the on-chip error reporting capability of the DS2181A. In the hardware mode, they
are the only alarm reporting means available.
RLOS
The RLOS output indicates the status of the receive synchronizer. When high, frame, CAS multiframe
and/or CRC4 multiframe synchronization is in progress. A high-low transition indicates resync is
complete. The RLOS bit (RSR.1) is a latched version of the RLOS output.
RRA
The remote alarm output transitions high when a remote alarm is detected. A high-low transition indicates
the alarm condition has been cleared. The alarm condition is defined as bit 3 of time slot 0 set for three
consecutive non-align frames. The alarm state is cleared when bit 3 has been clear for three consecutive
non-align frames. The RRA bit (RSR.7) is a latched version of the RRA Output.
RBV
RBV pulses high when the accused bit emerges at RSER. RBV will return low when RCLK goes low.
Bipolar violations are also logged in the BVCR. The RBV pin provides a pulse for every violation which
can be counted externally.
相关PDF资料
PDF描述
VE-B6T-MY-S CONVERTER MOD DC/DC 6.5V 50W
VI-26R-MY-S CONVERTER MOD DC/DC 7.5V 50W
DS275S IC TXRX LINE-PWR RS232 8-SOIC
VI-26M-MY-S CONVERTER MOD DC/DC 10V 50W
MS27473E18B11PB CONN PLUG 11POS STRAIGHT W/PINS
相关代理商/技术参数
参数描述
DS2181AQN/T&R 制造商:Maxim Integrated Products 功能描述:CEPT TRANSCEIVER-PLCC-IND-TRL - Tape and Reel 制造商:Rochester Electronics LLC 功能描述: 制造商:Maxim Integrated Products 功能描述:IC TXRX CEPT PRIM RATE IN 44PLCC 制造商:Maxim Integrated Products 功能描述:Network Controller & Processor ICs CEPT Primary Rate Transceiver
DS2181AQN/T&R+ 制造商:Maxim Integrated Products 功能描述:CEPT TRANSEIVER PLCC IND TRL LF - Tape and Reel
DS2181AQN/T&R 功能描述:网络控制器与处理器 IC CEPT Primary Rate Transceiver RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS2181AQN+ 功能描述:网络控制器与处理器 IC CEPT Primary Rate Transceiver RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
DS2181AQN+T&R 制造商:Maxim Integrated Products 功能描述: 制造商:Maxim Integrated Products 功能描述:CEPT TRNSCVR 1TX 1RX 44PLCC - Tape and Reel 制造商:Maxim Integrated Products 功能描述:IC TXRX CEPT PRIMARY RATE 44PLCC 制造商:Maxim Integrated Products 功能描述:Network Controller & Processor ICs CEPT Primary Rate Transceiver