参数资料
型号: DS2780E+T&R
厂商: Maxim Integrated Products
文件页数: 24/31页
文件大小: 0K
描述: IC FUEL GAUGE BATT 8TSSOP
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
功能: 燃料,电量检测计/监控器
电池化学: 锂离子(Li-Ion)、锂聚合物(Li-Pol)
电源电压: 2.5 V ~ 5.5 V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 8-TSSOP(0.173",4.40mm 宽)
供应商设备封装: 8-TSSOP
包装: 带卷 (TR)
DS2780 Standalone Fuel Gauge IC
TRANSACTION SEQUENCE
The protocol for accessing the DS2780 through the 1-Wire port is as follows:
?
?
?
?
Initialization
Net Address Command
Function Command
Transaction/Data
additional iterations of the process. See Chapter 5 of the Book of DS19xx iButton Standards for a comprehensive
The sections that follow describe each of these steps in detail.
All transactions of the 1-Wire bus begin with an initialization sequence consisting of a reset pulse transmitted by the
bus master followed by a presence pulse simultaneously transmitted by the DS2780 and any other slaves on the
bus. The presence pulse tells the bus master that one or more devices are on the bus and ready to operate. For
more details, see the 1-Wire Signaling section.
NET ADDRESS COMMANDS
Once the bus master has detected the presence of one or more slaves, it can issue one of the net address
commands described in the following paragraphs. The name of each ROM command is followed by the 8-bit
opcode for that command in square brackets. Figure 21 presents a transaction flowchart of the net address
commands.
Read Net Address [33h or 39h]. This command allows the bus master to read the DS2780’s 1-Wire net address.
This command can only be used if there is a single slave on the bus. If more than one slave is present, a data
collision occurs when all slaves try to transmit at the same time (open drain produces a wired-AND result). The
RNAOP bit in the status register selects the opcode for this command, with RNAOP = 0 indicating 33h, and
RNAOP = 1 indicating 39h.
Match Net Address [55h]. This command allows the bus master to specifically address one DS2780 on the 1-Wire
bus. Only the addressed DS2780 responds to any subsequent function command. All other slave devices ignore
the function command and wait for a reset pulse. This command can be used with one or more slave devices on
the bus.
Skip Net Address [CCh]. This command saves time when there is only one DS2780 on the bus by allowing the
bus master to issue a function command without specifying the address of the slave. If more than one slave device
is present on the bus, a subsequent function command can cause a data collision when all slaves transmit data at
the same time.
Search Net Address [F0h]. This command allows the bus master to use a process of elimination to identify the 1-
Wire net addresses of all slave devices on the bus. The search process involves the repetition of a simple three-
step routine: read a bit, read the complement of the bit, then write the desired value of that bit. The bus master
performs this simple three-step routine on each bit location of the net address. After one complete pass through all
64 bits, the bus master knows the address of one device. The remaining devices can then be identified on
?
discussion of a net address search, including an actual example. (This publication can be found on the
Maxim/Dallas Semiconductor website at www.maxim-ic.com.)
Resume [A5h] . This command increases data throughput in multidrop environments where the DS2780 needs to
be accessed several times. Resume is similar to the Skip Net Address command in that the 64-bit net address
does not have to be transmitted each time the DS2780 is accessed. After successfully executing a Match Net
Address command or Search Net Address command, an internal flag is set in the DS2780. When the flag is set,
the DS2780 can be repeatedly accessed through the Resume command function. Accessing another device on the
bus clears the flag, thus preventing two or more devices from simultaneously responding to the Resume command
function.
iButton is a registered trademark of Maxim Integrated Products, Inc.
24 of 31
相关PDF资料
PDF描述
ATAVRXPLAIN KIT EVAL FOR ATXMEGA128A1
DS2764BE+T&R IC MON BATT LI-ION HP 16-TSSOP
1435864-9 PATCHCORD CAT6 BLK/BLK BOOT 9'
1499740-3 CABLE/ASSY AMPTRAC SHLD CAT6 3FT
DS2764AE+T&R IC MON BATT LI-ION HP 16-TSSOP
相关代理商/技术参数
参数描述
DS2780EVKIT+ 制造商:Maxim Integrated Products 功能描述:DS2780 EVAL KIT - Boxed Product (Development Kits)
DS2780G+ 功能描述:电池管理 Stand-Alone Fuel Gauge RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
DS2780G+T&R 制造商:Maxim Integrated Products 功能描述:STANDALONE FUELGAUGE 10-TDFN T&R LF - Tape and Reel 制造商:Maxim Integrated Products 功能描述:IC FUEL GAUGE STAND ALONE 10TDFN 制造商:Maxim Integrated Products 功能描述:Battery Management Stand-Alone Fuel Gauge
DS2780G+T&R 功能描述:电池管理 Stand-Alone Fuel Gauge RoHS:否 制造商:Texas Instruments 电池类型:Li-Ion 输出电压:5 V 输出电流:4.5 A 工作电源电压:3.9 V to 17 V 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:VQFN-24 封装:Reel
DS2780G+TR 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Standalone Fuel Gauge IC