Original specifications created by Sharp.
14
Panelview Hillsboro, OR (503) 690-2460
Panelview is a subsidiary of White Electronic Designs Corporation
ENH064V1-300/450
Panelview
Enhancing the Vision
RELIABILITY TEST ITEMS
No.
Test item
Conditions
1
High Temperature Storage Test
Ta=70°C
240h
2
Low Temperature Storage Test
Ta=25°C
240h
3
High Temperature &
Ta=40°C, 95%RH
240h
High Humidity Operation Test
(No Condensation)
4
High Temperature Operation Test
Ta=55°C
240h
5
Low Temperature Operation Test
Ta=0°C
240h
6
Vibration Test
Frequency
:10~57Hz/Vibration width (one side):0.075mm
(Non-Operating)
:58~500Hz/Gravity: 9.8m/s2
Sweep time
:11 minutes
Test period
:3 hours (1 hour for each direction of X,Y,Z)
7
Shock Test
Max. gravity
:490m/s2
(Non-Operating)
Pulse width
:11ms, half sine wave
Direction
:±X, ±Y, ±Z (once for each direction.)
DISPLAY QUALITY
The display quality of the color TFT-LCD module shall
be in compliance with the Incoming Inspection Standard.
HANDLING PRECAUTIONS
1) Be sure to turn off the power supply when inserting
or disconnecting the cable.
2) Design the cabinet so that the module can be
installed without any extra stress such as warp or
twist.
3) Since the front polarizer is easily damaged, pay
attention to avoid rubbing with something hard or
sharp.
4) Wipe water off immediately. Long contact with water
may cause discoloration or spots.
5) When the panel surface is soiled, use an absorbent
cotton or other soft cloth to wipe it off.
6) Since the panel is made of glass, refined wires
and components, it may break, crack or cause
internal wire breaking if dropped or bumped on hard
surface. Handle with care.
7) Since CMOS LSI is used in this module, make
certain one is grounded when handling.
8) Observe all other precautionary requirements in
handling components.
9) This module has its circuitry PCBs on the rear side
and should be carefully handled in order to avoid
being stressed.
10) Laminated film is attached to the module surface
to prevent it from being scratched. Before use, peel
the film off slowly, with strict attention to electrostatic
charges. Ionized air shall be blown over during the
action. Blow off dust on the polarizer by using an
ionized nitrogen gun.
11) Connect GND to 4 place of mounting holes to
stabilize against EMI and external noise.
12) The high voltage portions on the backlight are very
dangerous. Careless handling may lead to electrical
shock.
PACKING FORM
1) Piling number of cartons: MAX 10
2) Package quantity in one carton: 20pcs
3) Carton size: 355 (W) X 282 (D) X 265 (H) mm
4) Total mass of 1 carton filled with full modules: 7.0kg
OTHERS
1) Disassembling the module can cause permanent
damage and should be avoided.
2) Image retention may occur when a fixed pattern is
displayed for a long time.
EXCHANGE OF LAMPS
This must be action must be performed by Panelview.