PIPING
5
The outer diameter of the air-tube to fit to the air inlet portion of this product
should be
6mm.
Make sure that clean air (air containing no-water, no-oil and no dust) should
be supplied.
Since the pressure will drop when the air piping from the main pressure sup-
ply is extended or pneumatic-components (e.g., needle valve, spin core, mini
filter) are added, keep an eye on the pressure supply to the ionizer making
sure it isn't in short supply. For the pneumatic- components, select those that
can accommodate the air supply flow rate.
OPERATION MATRIX
8
Notes: 1)
2)
3)
'DSC OFF' input in the 'ERROR' state is invalid (since the 'ERROR' state is prioritized).
'RESET' input is enabled even when in the 'DSC OFF' input state, and 'DSC 'OFF' input
remains unaffected by 'RESET' input.
'RESET' input in the 'ERROR' state resumes the 'ERROR' state unless the cause of the
error has been eliminated.
N.O.
N.C.
Red
OFF
ON
OFF
ON
OFF
Discharge
through
needle
(Maintained)
ON
OFF
ON
(Allowed)
Check
Error
Output
(Maintained)
Green
Orange
Power
Discharge
Error
Check
Indicators (
Lights up
OFF)
Discharge halt input
Error
Check
Normal
Reset input
Make sure that the power supply is off while checking the high-
voltage part. Otherwise, you may get an electric shock.
WARNING
TROUBLE SHOOTING
10
Doesn't go back to
normal state by reset
Symptom
Remedy
Check indicator
(orange)
lights up
Make sure that the power voltage is within the tolerance as per specifications.
Abnormal discharge is possible.
Turn off the power supply, check the tip of the discharge needle for chip and
contamination, and make sure that the discharge needle unit is mounted
normally on the main body. Also, check the inside of the nozzle for foreign
objects, and make sure that the nozzle is mounted and installed properly.
Make sure that the ground terminal is connected completely.
Make sure that the power voltage is within the tolerance as per specifications.
Check the tip of the discharge needle for chip and contamination, and make
sure that the discharge needle unit is mounted normally on the main body.
If the CHECK indicator (orange) lights up even after cleaning the
discharge needle, also check the nozzle part for contamination.
Make sure that the nozzle assembly (including the attachment and
the resin tube) is mounted properly.
Make sure that the air pressure is within the applicable range as per specifications.
Make sure that the cause of the error has been eliminated.
Error indicator
(red) lights
up
INPUT SIGNAL CONDITIONS
7
Conditions for the discharge halt input and the reset input are as follows.
Note: Repeat control with 'DSC OFF' input
should be 1Hz or less.
Discharge halt input
0.5 sec.
or more
Low
Open
DSC OFF
(Low input)
Reset input
Low
Open
10ms
or more
10ms
or more
RESET
(Start-up input)
Before checking the high-voltage part, be sure to turn off the
power supply, or you may get an electric shock.
Since the tip of the discharge needle is pointed, take sufficient
care when cleaning. There is a danger of injury.
WARNING
MAINTENANCE
9
Since the removal discharge effect will deteriorate if dirt is stuck to the tip of
the discharge needle, clean the discharge needle periodically.
The maintenance required depends on the environment of use. As a refer-
ence, the maintenance should be done once in two weeks.
The discharge needle is a part having a product life time. It is recommended
that the needle should be replaced, as a reference, after 10,000 hours in
use. When replacing it, replace the whole unit.
Confirm that the power supply is off.
Unscrew the discharge needle counter-
clockwise.
Remove the dirt on and around the dis-
charge needle with a cotton bud soaked in
alcohol.
After cleaning, screw the needle clockwise to fit. The tightening torque
should be 0.3N m or less.
Procedure of cleaning and replacing the discharge needle
Discharge needle unit
Connector pin arrangement
(Front view)
Blue
Pink
Violet
Brown
Orange
Black
0V
COM
Discharge halt input
Reset input
24V
COM
Check output
Error output
Terminal No.
Terminal
Color code
I/O CIRCUIT DIAGRAMS
6
Symbols... D: Reverse supply polarity protection diode
ZD1, ZD2:
Tr1,Tr2:
Surge absorption zener diode
NPN output transistor
*1
or
Discharge halt input
Low (0V): Discharge halt
High (Open): Discharge allowed (Operation starts)
Reset input
In the state that operation is stopped due to an error detection, open 0V of the
power supply from short-circuit state to cancel ERROR
Non-voltage contact or NPN open-collector transistor
Internal circuit
Users' circuit
Ground
terminal
D
(Brown) +V
24V DC
10%
(Pink) Discharge halt input
(Violet) Reset input
*1
COM (-)
COM (+)
(Blue) 0V
Terminal connecter No.
Color code
Load
(Orange) Check output
(Black) Error output
Tr1
ZD1
Tr2
ZD2
50mA max.
Sensor
circuit
PRINTED IN JAPAN
Head Office
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
Overseas Sales Dept.
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
http://www.sunx.co.jp/
SUNX Limited
DIMENSIONS (Unit: mm)
11
Mounting drawing with shower nozzle (optional)
Discharge indicator
(Green)
5559-08P manufactured
by Molex 5559-08P
2-
4.5 mounting holes
Power indicator (Green)
PCC6-M8M manufac-
tured by PISCO
4.2 cable 0.5m (gray)
Ground terminal
(M3)
Error indicator (Red)
Check indicator (Orange)
5.2
(4.5)
4.5
100
2.8
5.5
11.7
16
27
10
89
31.7
12.3
14.3
Shower nozzle (ER-VAS) (optional)
4.3
18.8
28
11.3
5.8
11.4
17.8
Airflow outlet
This product cannot be used by its own. Be sure to fit the optional
nozzle for use of this product.
For the details of the optional nozzle, refer to the instruction
manual enclosed with the nozzle.
Since a protective film is affixed on the
nozzle fitting part, be sure to remove it
before fitting the nozzle (optional). The
tightening torque should be 6N m or less.
Shower nozzle (ER-VAS) (optional)
ER-VS01
Attachment
Convex
part
Resin tube
(Enclosed with nozzle)
Protective film
相关PDF资料
PDF描述
ER-VWCC2 CABLE W/ CONNECTOR 2M LENGTH
ES155 HEAVY DUTY DEGREASER
FPSNAP PRONG SNAP 3/8" SOCKET
FSG1M-S FRONT SOLE GROUNDER ASMBLY W/RES
GT-0901A BUZZER 2.73KHZ 1-3V EXT DRIVE
相关代理商/技术参数
参数描述
ER-VS02 功能描述:ULTRA-COMPACT IONIZER 制造商:panasonic industrial automation sales 系列:ER-VS 零件状态:有效 类型:电离器 安装类型:台式,悬挂式 电压 - 输入:24VDC 标准包装:1
ER-VW 功能描述:ULTRA THIN IONIZER DUAL NOZZLE RoHS:是 类别:静电控制,ESD,无尘室产品 >> 电离装置 系列:ER-VW, SUNX 标准包装:1 系列:- 类型:可调式臂杆 安装类型:C 钳 输入电压:- 其它名称:A60460
ER-VWANT 功能描述:DISCHARGE REPLACEMENT NEEDLE RoHS:是 类别:静电控制,ESD,无尘室产品 >> 电离装置 系列:ER-VW, SUNX 标准包装:1 系列:- 类型:可调式臂杆 安装类型:C 钳 输入电压:- 其它名称:A60460
ER-VWAR80 制造商:PANASONIC ELECTRIC WORKS ACSD 功能描述:Ionizer, ER-VW Series, Joint Kit, Connection Cable and Air Tube Joint, 1 of Each 制造商:PANASONIC ELECTRIC WORKS - ACSD 功能描述:JOINT KIT CONNECT CBL/AIR TUBE
ER-VWCC2 功能描述:CABLE W/ CONNECTOR 2M LENGTH RoHS:是 类别:静电控制,ESD,无尘室产品 >> 配件 系列:ER-VW, SUNX 标准包装:1 系列:durAstatic™ 附件类型:瓶 适用于相关产品:液体 技术规格:8盎司,耗散,绿色,包含手扣式喷头