AD5380
Rev. C | Page 23 of 40
Table 15. Control Register Contents
MSB
LSB
CR13
CR12
CR11
CR10
CR9
CR8
CR7
CR6
CR5
CR4
CR3
CR2
CR1
CR0
Control Register Write/Read
REG1 = REG0 = 0, A5 to A0 = 001100, R/W status determines
if the operation is a write (R/W = 0) or a read (R/W = 1). DB13
to DB0 contains the control register data.
Control Register Contents
CR13: Power-Down Status. This bit is used to configure the
output amplifier state in power down.
CR13 = 1. Amplifier output is high impedance (default on
power-up).
CR13 = 0. Amplifier output is 100 k to ground.
CR12: REF Select. This bit selects the operating internal
reference for the AD5380. CR12 is programmed as follows:
CR12 = 1: Internal reference is 2.5 V (AD5380-5 default),
the recommended operating reference for AD5380-5.
CR12 = 0: Internal reference is 1.25 V (AD5380-3 default),
the recommended operating reference for AD5380-3.
CR11: Current Boost Control. This bit is used to boost the
current in the output amplifier, thereby altering its slew rate.
This bit is configured as follows:
CR11 = 1: Boost Mode On. This maximizes the bias current
in the output amplifier, optimizing its slew rate but increasing
the power dissipation.
CR11 = 0: Boost Mode Off (default on power-up). This
reduces the bias current in the output amplifier and reduces
the overall power consumption.
CR10: Internal/External Reference. This bit determines if the
DAC uses its internal reference or an externally applied
reference.
CR10 = 1: Internal Reference Enabled. The reference output
depends on data loaded to CR12.
CR10 = 0: External Reference Selected (default on power-up).
CR9: Channel Monitor Enable (see Channel Monitor Function).
CR9 = 1: Monitor Enabled. This enables the channel monitor
function. After a write to the monitor channel in the SFR
register, the selected channel output is routed to the
MON_OUT pin. VOUT39 operates as the MON_OUT pin.
CR9 = 0: Monitor Disabled (default on power-up). When the
monitor is disabled, the MON_OUT pin assumes its normal
DAC output function.
CR8: Thermal Monitor Function. This function is used to
monitor the AD5380’s internal die temperature when enabled.
The thermal monitor powers down the output amplifiers when
the temperature exceeds 130°C. This function can be used to
protect the device in cases where power dissipation may be
exceeded if a number of output channels are simultaneously
short-circuited. A soft power-up will re-enable the output
amplifiers if the die temperature has dropped below 130°C.
CR8 = 1: Thermal Monitor Enabled.
CR8 = 0: Thermal Monitor Disabled (default on power-up).
CR7: Don’t Care.
CR6 to CR2: Toggle Function Enable. This function allows the
user to toggle the output between two codes loaded to the A
and B registers for each DAC. Control Register Bits CR6 to CR2
are used to enable individual groups of eight channels for
operation in toggle mode. A Logic 1 written to any bit enables
a group of channels; a Logic 0 disables a group. LDAC is used to
toggle between the two registers. Table 16 shows the decoding
for toggle mode operation. For example, CR6 controls Group w,
which contains Channel 32 to Channel 39, CR6 = 1 enables
these channels.
CR1 and CR0: Don’t Care.
Table 16.
CR Bit
Group
Channels
CR6
4
32–39
CR5
3
24–31
CR4
2
16–23
CR3
1
8–15
CR2
0
0–7
Channel Monitor Function
REG1 = REG0 = 0, A5 to A0 = 001010
DB13 to DB8 = Contain data to address the monitored channel.
A channel monitor function is provided on the AD5380. This
feature, which consists of a multiplexer addressed via the inter-
face, allows any channel output to be routed to the MON_OUT
pin for monitoring using an external ADC. In channel monitor
mode, VOUT39 becomes the MON_OUT pin, to which all
monitored pins are routed. The channel monitor function must
be enabled in the control register before any channels are routed
to MON_OUT. On the AD5380, DB13 to DB8 contain the
channel address for the monitored channel. Selecting Channel
Address 63 three-states MON_OUT.
相关PDF资料
PDF描述
RSM06DTKN CONN EDGECARD 12POS DIP .156 SLD
REF195GSZ-REEL7 IC VREF SERIES PREC 5V 8-SOIC
EVAL-AD5764EBZ BOARD EVAL FOR AD5764
RSM06DTKH CONN EDGECARD 12POS DIP .156 SLD
REF192GSZ-REEL7 IC VREF SERIES PREC 2.5V 8-SOIC
相关代理商/技术参数
参数描述
EVAL-AD5381EB 制造商:Analog Devices 功能描述:EVAL KIT FOR 40-CH, 3V/5 V, SGL-SUPPLY, 12-BIT, VOLT OUTPUT - Bulk 制造商:Rochester Electronics LLC 功能描述:
EVAL-AD5382EB 制造商:Analog Devices 功能描述:EVALUATION BOARD I.C. - Bulk 制造商:Rochester Electronics LLC 功能描述:
EVAL-AD5382EBZ 功能描述:BOARD EVAL FOR AD5382 RoHS:是 类别:编程器,开发系统 >> 评估板 - 数模转换器 (DAC) 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:1 系列:- DAC 的数量:4 位数:12 采样率(每秒):- 数据接口:串行,SPI? 设置时间:3µs DAC 型:电流/电压 工作温度:-40°C ~ 85°C 已供物品:板 已用 IC / 零件:MAX5581
EVAL-AD5383EB 制造商:Analog Devices 功能描述:EVAL KIT FOR 32CH, 3V/5 V, SGL-SUPPLY, 12-BIT, VOLT OUTPUT D - Bulk 制造商:Rochester Electronics LLC 功能描述:
EVAL-AD5390EB 制造商:Analog Devices 功能描述: