RELIABILITY DATA
7/9
Item
LA02 Type/
LA03 Type
Specified Value
Test Method and Remarks
22.Resisitance to solvent
23.Thermnal shock
FBD
Solvent temperatureD20V25C
DurationD30M5 sec.
Solvent typeDAcetone, trichloroethylene
RecoveryD3hrs of recovery under the standard condition
after the test.
LAD
Conditions for 1cycle
Step
TemperaturefCg
Durationfming
1
K
25
30M3
2
Room temperature
Within 3
3
J
85
30M3
4
Room temperature
Within 3
Number of cyclesD5 cycles
RecoveryDAt least 1hr of recovery under the standard
condition after the removal from test chamber,
followed by the measurement within 2hrs.
LHLYLHFYFBD
Accoding to JIS C0025
Conditions for 1 cycle
Step
TemperaturefCg
Durationfming
1
Minimum operating
30M3
temperature
2
Room temperature
Within 3
3
Maximum oparating
30M3
temperature
4
Room temperature
Within 3
Number of cyclesD10 cycles
LHL
, LHF
BB, LHF15BB
D5 cyclesfFBA, FBRg
RecoveryD4 to 24hrs of recovery under the standard con-
dition after the removal from the test cfamber.
LHL
, LHF
BB, LHF15BB
D3hrs of recovery under the standard condition af-
ter the removal from the test cfamber.fFBA, FBRg
LAVD
Conditions for 1 cycle
Step
TemperaturefCg
Durationfming
1
Minimum operating
30M3
temperature
2
Room temperature
Within 3
3
Maximum oparating
30M3
temperature
4
Room temperature
Within 3
Number of cyclesD10 cycles
RecoveryDAt least 1hr of recovery under the standard
condition after the removal from test chamber,
followed by the measurement within 2hrs.
FLD
Accoding to JIS C0025
Conditions for 1 cycle
Step
TemperaturefCg
Durationfming
1
K
25
30M3
2
Room temperature
Within 3
3
J
85
30M3
4
Room temperature
Within 3
Number of cyclesD10 cycles
RecoveryD1 to 2hrs of recovery under the standard con-
dition after the removal from the test cfamber.
LA05 Type
LHL
/
LHF15BB/
LHFP
BB
FBA/FBR
LAV35
LA04 Type
L/LD
WithinM10L
QD30min.
AppearanceD
No abnor-
mality
Inductance
changeD
WithinM10L
Q changeD
WithinM30L
FL05
Type
FL06BT
Type
Please
avoid the ul-
trasonic
cleaning of
this product.
L/LD
WithinM10L
QD20min.
No signifi-
cant abnor-
mality in ap-
pearance
Impedance
changeD
WithinM20L
AppearanceD
No abnor-
mality
Impedance
changeD
WithinM20L
Refer to
individual
specifica-
tion
L/LD
WithinM10L
Q/QD
WithinM30L
L/LD
WithinM10L
QD15min.
AppearanceD
No abnor-
mality
Impedance
changeD
WithinM20L
Pleasa avoid the ultrasonic cleaning of
this product.