Power Supplies
F Series FCP/FCP-B
AC Input
Multi Output, General-Purpose
FCP-B10W TYPE
SPECIFICATIONS AND STANDARDS
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might
possibly not be satisfied when output is below the minimum output current.
3 Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
Part No.
FCP-101B
FCP-102B
Rated output voltage
and current1
V1
+12V 0.4A
+15V 0.32A
V2
–12V 0.4A
–15V 0.32A
Maximum output power
W
9.6
Input conditions
Input voltage Eac
V
85 to 132[Rating: 100 to 120]
Input frequency
Hz
47 to 66[Rating: 50 to 60](Single phase)
Input current
A
0.25typ.[25°C, input and output ratings](AC.85V input, rated output: 0.1max.)
Surge current
A
16max.[25°C, input and output ratings, cold start]
Leakage current
mA
0.5max.[25°C, input and output ratings]
Efficiency2
%
75typ.[25°C, input and output ratings]
Output characteristics
Rated output voltage Edc
V
+12[V1]
–12[V2]+15[V1]
–15[V2]
Voltage variable range Edc
V
10.8 to 13.2[V2 varies simultaneously as V1.]
13.5 to 16.5[V2 varies simultaneously as V1.]
Maximum output current
A
0.4
0.32
Minimum output current2
A
0.04
0.03
Output setting
conditions
[Voltage]
V
12.1
—
15.1
—
[Current]
A
0.4
0.32
Voltage
stability
Source effect
%
0.1typ.[Within the input voltage range]
Total effect ±3max.(±1typ.)
Load effect
%
0.8typ.[10 to 100% load]
Temperature effect
%
1typ.[Ambient temperature: 0 to +50°C]
Drift(Time effect)
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%/ms
±4max./1max.[50 to 100% sudden load change]
Ripple Ep-p
mV
80
Ripple noise Ep-p
mV
150
Start up time
ms
100max.
Hold up time
ms
20min.
Auxiliary functions
Indicator display
No
Overvoltage protection
Uses overvoltage prevention3
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Output voltage external variable function
No
Standards
Safety standards
—
Noise terminal voltage
FCC class B meet.
Constructions
External dimensions
mm
19
×55×80[H×W×L](Except input and output terminals)
Weight
g
100max.
Mounting method
Can be attached to 1 side.
Case and cover
Nonflammable resin
Input and output cables
—