1-phase lters
FN 2060
Multi-stage general purpose EMI lter
Approvals
■
Rated currents from 1 to 30A
■
High differential and common-mode
attenuation
■
Optional medical versions (B type)
■
Optional safety versions (A type)
Typical applications
■
FN 2060 two-stage filters are designed for
easy and fast chassis mounting.
■
FN 2060 filters are also available as B
versions without Y-capacitors for medical
applications as well as A version with low
capacitance for safety critical applications
with necessity for low leakage currents.
■
All filters provide a high conducted
attenuation performance, based on chokes
with high saturation resistance and
excellent thermal behavior.
■
FN 2060 two-stage filters are designed for
noisy applications requiering good
differential and common-mode attenuation.
■
FN 2060 filters are also available as single-
stage filters (FN 2010 series).
■
Various terminal options allow you to
select the desired connection style.
■
Electrical and electronic equipment
■
Consumer goods
■
Household equipment
■
Building automation
■
Industrial applications
■
Machinery
■
Medical equipment
■
Electronic data processing equipment
■
Office automation and datacom equipment
■
Various noisy applications requiering good
filter performance
Features and benefits
Technical specifications
Maximum continuous operating voltage:
250VAC, 50/60Hz
Operating frequency:
dc to 400Hz
Rated currents:
1 to 30A @ 40°C max.
High potential test voltage:
P –> E 2000VAC for 2 sec
P –> E 2500VAC for 2 sec (B types)
P –> N 1100VDC for 2 sec
Temperature range (operation and storage):
-25°C to +100°C (25/100/21)
Flammability corresponding to:
UL 94V-2 or better
Design corresponding to:
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 40°C/230V (Mil-HB-217F):
950,000 hours
1,650,000 hours (B types)
Typical electrical schematic
P
N
E
Line
Cx
R
LL
P‘
N‘
Load
Cx
Cy