Technical Specifications
Description
Features
FRD DC-DC Series Data Sheet
Dual-Output, 5 Watts
REV. JAN 31, 2006
Page 1 of 2
www.power-one.com
FRD dual output DC-DC converters offer excellent
regulation and isolation in an industry-standard package.
Available in several input versions, the FRD is perfect for
industrial, datacom, or telecom applications.
The FRD
features short-circuit protection, six-sided shielding, and
500 VDC isolation.
Wide input range
Trim and enable pins
Remote sense pins
500 V isolation
Short-circuit protection
6-sided shielding
25
30
35
40
45
50
55
60
65
70
10
20
30
40
50
60
70
80
90
10
LOAD %
EFFICIENCY
%
EFF. FRD4812
EFF. FRD4815
35
40
45
50
55
60
65
70
75
80
10
20
30
40
50
60
70
80
90
10
LOAD %
EFFICIENCY
%
EFF. FRD2812
EFF. FRD2815)
Efficiency vs. Load (48V Input)
Efficiency vs. Load (28V Input)
Notes
MTBF predictions may vary slightly from model to model.
Industrial temp range available
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Input
Voltage Range
5V, 12V, 24V, 28V, and 48V Nominal
See selection chart for specific input range.
Reflected Ripple
20% Iin Max.
Reverse Input Current
100% Iin Max.
General
Switching Frequency
20 kHz
Isolation
Input - Output
500 VDC
Isolation Resistance - Input to Output
109 Ohms
Case Temperature
Operating Range
-25 To +85 °C
Storage Range
-40 To +125 °C
Humidity Max, Non-Condensing
95%
Temperature Coefficient
±0.02%/°C
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
Safety
Consult Factory
Weight (Approx.)
2.2 oz
Output
Setpoint Accuracy
±1% Vout
Line Regulation Vin Min. - Vin Max., Iout Rated
±0.15% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom.
±0.15% Vout Iout
Rated
Minimum Output Current
10 % lout Rated
Short Circuit Protection1
Continuous