Micrel, Inc.
SY55859L
January 2010
4
M9999-012110-A
Absolute Maximum Ratings
(1)
Supply Voltage (VCC) ..................................... -0.5V to +6.0V
CML Input Voltage (VIN). ............................... -0.5V to +6.0V
TTL Control Input Voltage (VIN).............. -0.5V to VCC +0.5V
CML Output Voltage (VOUT)............. VCC -1.0V to VCC +0.5V
CML Output Current (IOUT) ..........................................22mA
Lead Temperature (soldering, 20sec.) ..................... +260°C
Storage Temperature (TS).........................–65°C to +150°C
Operating Ratings
(2)
Supply Voltage (VCC)..................................+3.0 to +3.6V
Ambient Temperature (TA)..................... –40°C to +85°C
Junction Temperature (TJ) .................................... 160°C
Package Thermal Resistance
QFN
(θ
JA)
Still-air……………………………………....28°C/W
500lfpm……………………………………..20°C/W
QFN
(θ
JC)………………………………………4°C/W
DC Electrical Characteristics
TA = –40°C to +85°C.
Symbol
Parameter
Condition
Min
Typ
Max
Units
VCC
Power Supply Voltage
3.0
3.3
3.6
V
ICC
Power Supply Current
No Load, Over Supply Voltage; All
Outputs Enabled
160
190
mA
CML DC Electrical Characteristics
VCC = 3.0V to 3.6V; GND = 0V; TA = –40°C to +85°C
(Note 3)
Symbol
Parameter
Condition
Min
Typ
Max
Units
VOUT
CML Differential Output Swing
RL = 50
to VCC, Figure 3
640
800
1000
mVPP
ROUT
Differential Output Impedance
Figure 2
85
100
115
VOCM
CML Output Common Mode
Voltage
RL = 50
to VCC, Figure 3
VCC-0.2
V
VIS
CML Input Voltage Range
Figure 4
VCC-0.8
VCC+0.4
V
VDIFF
CML Differential Input Voltage
Swing
Figure 5
300
1600
mVPP
CML Single-ended Input
Impedance
Figure 1
42.5
50
57.5
TTL Control Electrical Characteristics
VCC = 3.0V to 3.6V; GND = 0V; TA = –40°C to +85°C
(Note 3)
Symbol
Parameter
Condition
Min
Typ
Max
Units
VIH
TTL Input HIGH Voltage
2.0
V
VIL
TTL Input LOW Voltage
0.8
V
IIH
TTL Input HIGH Current
-10
+10
A
IIL
TTL Input LOW Current
-10
+10
A
Notes:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied
at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended
periods may affect reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. The device is guaranteed to meet the DC specifications, shown in the table above, after thermal equilibrium has been established. The device is
tested in a socket such that transverse airflow of
≥500lfpm is maintained.