G2RL
G2RL
3
3
APPROVED STANDARDS
UL508 (File No. E41515)/CSA C22.2 (No.14) (File No. LR31928)
Part number
Contact form
Coil ratings
3 to 48 VDC
3 o 8
Contact ratings
12 A at 250 VAC (General use), 100k ops.
12 A t 24 VDC (R
12 A at 24 VDC (Resistive), 50k ops.
G2RL-1A
G2RL-1
G2RL-1A-E
SPST-NO
SPDT
SPST-NO (High capacity)
i ti
) 50k
C (Ge e a use), 00 o s
16 A at 250 VAC (General use), 100k ops.
16 A at 24 VDC (Resistive), 50k ops.
16 A at 24 VDC (Resistive), 50k o s.
20 A at 240 VAC (General use), 85°C
15 A at 240 VAC (General use), 105°C
8 A at 277 VAC (General use), 100k ops.
8 A t 30 VDC (R
i ti
8 A at 30 VDC (Resistive), 100k ops.
G2RL-1-E
SPDT (High capacity)
G2RL-2A
G2RL-2
DPST-NO
DPDT
) 100k
C (Ge e a use), 00 o s
VDE (VDE0435)
Part number
G2RL
Contact form
Coil ratings
5, 12, 18, 22, 24, 48 VDC
Contact ratings
12 A at 250 VAC (cos
φ
=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 250 VAC (cos
φ
=1)
16 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
8 A at 250 VAC (cos
φ
=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
1 pole
1 pole (High capacity)
2 poles
Note: To achieve approved life cycles on sealed models, the relay should be vented by removing “knock off vent nib” on top of relay case
after the soldering/washing process.
Electrical Life Data
Part number
G2RL-1-E
Contact rating
16 A at 250 VAC (cos
φ
=1)
16 A at 24 VDC
8 A at 250 VAC (cos
φ
=0.4)
8 A at 30 VDC (L/R=7 ms)
12 A at 250 VAC (cos
φ
=1)
12 A at 24 VDC
5 A at 250 VAC (cos
φ
=0.4)
5 A at 30 VDC (L/R=7 ms)
8 A at 250 VAC (cos
φ
=1)
8 A at 30 VDC
Pilot duty (A300), 250 VAC
Pilot duty (A300), 125 VAC
Minimum operations
100,000 operations min. (1 sec. ON / 9 sec. OFF)
30,000 operations min.
200,000 operations min. (N.O. side operation)
10,000 operations min.
100,000 operations min. (1 sec. ON / 9 sec. OFF)
30,000 operations min.
150,000 operations min.
20,000 operations min.
100,000 operations min. (1 sec. ON / 9 sec. OFF)
30,000 operations min.
250,000 operations min. (1 sec. ON / 9 sec OFF)
150,000 operations min. (1 sec. ON / 9 sec OFF)
G2RL-1
G2RL-2
G2RL-1A-E
Note: 1.
The results shown reflect minimum cycles using a very severe duty cycle of 1 sec ON/1 sec OFF (unless otherwise specified
above).
In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the “knock off
vent nib” on top of the relay case after the soldering / washing process of the P.C.B.
Contact Omron for applications where venting of the sealed relay is not possible.
2.