Surface Mount
Monolithic Amplier
Page 1 of 4
ISO 9001 ISO 14001 CERTIFIED
Mini-Circuits
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661 For detailed performance specs & shopping online see Mini-Circuits web site
The Design Engineers Search Engine Provides ACTUAL Data Instantly From MINI-CIRCUITS At: www.minicircuits.com
RF/IF MICROWAVE COMPONENTS
minicircuits.com
ALL NE
W
Product Features
InGaP HBT microwave amplier
Miniature SOT-89 package
Frequency range, DC to 4 GHz
Output power, 18.0 dBm typ.
Excellent package for heat dissipation, exposed metal bottom
Low thermal resistance for high reliability
Aqueous washable
Protected by US Patent 6,943,629
Typical Applications
Cellular
PCS
Communication receivers & transmitters
simplied schematic and pin description
Function
Pin Number
Description
RF IN
1
RF input pin. This pin requires the use of an external DC blocking capacitor chosen
for the frequency of operation.
RF-OUT and DC-IN
3
RF output and bias pin. DC voltage is present on this pin; therefore a DC blocking
capacitor is necessary for proper operation. An RF choke is needed to feed DC bias
without loss of RF signal due to the bias connection, as shown in “Recommended
Application Circuit”.
GND
2,4
Connections to ground. Use via holes as shown in “Suggested Layout for PCB
Design” to reduce ground path inductance for best performance.
General Description
Gali 5+ (RoHS compliant) is a wideband amplier offering high dynamic range. Lead nish is SnAgNi. It
has repeatable performance from lot to lot, and is enclosed in a SOT-89 package. It uses patented Tran-
sient Protected Darlington conguration and is fabricated using InGaP HBT technology. Expected MTBF
is 3,000 years at 85°C case temperature. Gali 5+ is designed to be rugged for ESD and supply switch-on
transients.
GROUND
RF IN
RF-OUT and DC-IN
REV. Q
M108520
D60129
EE-7974Q
GALI-5+
RS/YB/FL
070126
DC-4 GHz
CASE STYLE: DF782
PRICE: $1.49 ea. QTY. (25)
Gali 5+
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Sufx has been added in order to identify RoHS
Compliance. See our web site for RoHS Compliance
methodologies and qualications.
3 RF-OUT & DC-IN
2 GROUND
1 RF-IN
4