HA179L00 Series
9
HA179L12P, HA179L12, HA179L12U
(V
IN
= –19 V, I
OUT
= 40 mA, 0°C
≤
Tj
≤ 125
°C, C
IN
= 0.33
μ
F, C
L
= 0.1
μ
F)
Item
Symbol
Min
Typ
Max
Unit
Test Condition
Output voltage
V
OUT
–11.52 –12
–12.48 V
Tj = 25
°
C
V
IN
= –19 V, 1.0 mA
≤
I
OUT
≤
70 mA
Tj = 25
°
C
–27 V
≤
V
IN
≤
–14.5 V
–27 V
≤
V
IN
≤
–16 V
Tj = 25
°
C
1.0 mA
≤
I
OUT
≤
150 mA
1.0 mA
≤
I
OUT
≤
100 mA
1.0 mA
≤
I
OUT
≤
40 mA
Tj = 25
°
C
Tj = 25
°
C
–27 V
≤
V
IN
≤
–16 V
1.0 mA
≤
I
OUT
≤
40 mA
Tj = 25
°
C
Tj = 25
°
C
–11.40 —
–12.60
Line regulation
V
OLINE
—
120
250
mV
—
100
200
Load regulation
V
OLOAD
—
28.5
—
mV
—
20
100
—
10
50
Quiescent current I
Q
Quiescent
current change
—
2.6
4.6
mA
I
Q
—
—
1.5
mA
—
—
1.0
Voltage drop
V
DROP
I
OS
—
1.3
—
V
Output short circuit
current
—
250
—
mA
HA179L15P, HA179L15, HA179L15U
(V
IN
= –23 V, I
OUT
= 40 mA, 0°C
≤
Tj
≤ 125
°C, C
IN
= 0.33
μ
F, C
L
= 0.1
μ
F)
Item
Symbol
Min
Typ
Max
Unit
Test Condition
Output voltage
V
OUT
–14.4
–15
–15.6
V
Tj = 25
°
C
V
IN
= –23 V, 1.0 mA
≤
I
OUT
≤
70 mA
Tj = 25
°
C
–30 V
≤
V
IN
≤
–17.5 V
–30 V
≤
V
IN
≤
–20 V
Tj = 25
°
C
1.0 mA
≤
I
OUT
≤
150 mA
1.0 mA
≤
I
OUT
≤
100 mA
1.0 mA
≤
I
OUT
≤
40 mA
Tj = 25
°
C
Tj = 25
°
C
–30 V
≤
V
IN
≤
–20 V
1.0 mA
≤
I
OUT
≤
40 mA
Tj = 25
°
C
Tj = 25
°
C
–14.25 —
–15.75
Line regulation
V
OLINE
—
130
300
mV
—
110
250
Load regulation
V
OLOAD
—
36
—
mV
—
25
150
—
12
75
Quiescent current I
Q
Quiescent
current change
—
2.6
4.6
mA
I
Q
—
—
1.5
mA
—
—
1.0
Voltage drop
V
DROP
I
OS
—
1.3
—
V
Output short circuit
current
—
240
—
mA