![](http://datasheet.mmic.net.cn/200000/HBD060ZGE-AN81H_datasheet_15067043/HBD060ZGE-AN81H_3.png)
Page 3 of 3
REV. SEP 05, 2003
OPTIONS
OPTION
SUFFIX
APPLICABLE SERIES
REMARKS
Negative Logic
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD
TTL "High" Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Pin Length and Heatsink Options
Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length
8
All Leaded Models
0.150" (3.8mm) Pin Length
9
All Leaded Models
0.24" (6.1mm) Horizontal Heatsink
1H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink
1V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink
2H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink
2V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink
3H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink
3V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
This page is offered as a reference. Consult factory for actual availability of options. When ordering equip-
ment options, use the following suffix information. Select preferred option(s) and add the suffix to the model
number. Ordering option examples are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equip-
ment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.