![](http://datasheet.mmic.net.cn/190000/HL1-PS-K_datasheet_14914689/HL1-PS-K_1.png)
HL
SPECIFICATIONS
TYPICAL APPLICATIONS
15A (1C), 10 A (2C)
SPACE SAVING
POWER RELAY
HL RELAYS
mm inch
27.2
1.071
35.4
1.394
20.8
.819
RoHS Directive compatibility information
http://www.nais-e.com/
FEATURES
High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
Rugged construction for tough applications
Long life
Mechanical: Min. 108 operations (DC),
Min. 5
× 107 operations (AC)
Electrical: Min. 5
× 105 operations (Except for 10 A 250 V AC of 2 Form C)
About Cd-free contacts
We have introduced Cadmium free type products to reduce Environmental Hazardous
Substances.
(The sufx “F” should be added to the part number)
Please replace parts containing Cadmium with Cadmium-free products and evaluate
them with your actual application before use because the life of a relay depends on the
contact material and load.
Contacts
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specications will vary with foreign standards certication ratings.
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10 mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10
s
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10
s
Characteristics (at 25
°C 77°F, 50% Relative humidity)
Arrangement
1 Form C
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Contact material
AgSnO2 type
Rating
(resistive)
Nominal switching
capacity
15 A 125 V AC,
10 A 250 V AC
Max. switching power
AC: 2,500 VA
DC: 90 W
AC: 2,500 VA
DC: 90 W
Max. switching voltage
250 V AC
30 V DC
250 V AC
30 V DC
Max. switching current
15 A
10 A
Min. switching capacity#1
100 mA, 5 V DC
Expected
life
Mechanical (at 180 cpm)
5
×107 (AC), 106 (DC)
Electrical
(resistive)
15 A 125 V
AC
5
×105
—
10 A 250 V
AC
5
×105
3
×105
3 A 30 V DC
5
×105
5
×105
Max. operating speed
20 cpm
Initial insulation resistance*1
Min. 100 M
(at 500 V DC)
Initial
breakdown
voltage*2
Between contact sets
1,500 Vrms for 1 min.
Between open contacts
1,000 Vrms for 1 min.
Between contacts and coil
2,000 Vrms for 1 min.
Operate time (at nominal voltage)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Release time*3 (without diode)
(at nominal voltage)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Temperature rise, max.
(at nominal voltage)
Max. 80
°C
Shock resistance
Functional*4
Min. 196 m/s2 {20 G}
Destructive*5
Min. 980 m/s2 {100 G}
Vibration resistance
Functional*6
10 to 55 Hz
at double amplitude of 1 mm
Destructive
10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage*7
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–50
°C to +70°C
–58
°F to +158°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 35 g 1.25 oz
Power station control equipment, refrigerators, building control
equipment, ofce machines, and medical equipment.
All Rights Reserved C
OPYRIGHT Matsushita Electric Works, Ltd.