参数资料
型号: HX 50-P
厂商: LEM USA Inc
文件页数: 1/3页
文件大小: 0K
描述: SENSOR CURRENT 50A -/+15V MOD
产品目录绘图: HX50-P Side
标准包装: 50
系列: HX
电流 - 感应: 50A
精确度: <±1%
电流 - 电源: <±15mA
传感器类型: 开环霍尔效应
电源电压: -15 V ~ 15 V
输出: ±4V
频率: 50kHz
响应时间: <3µs
电极标记: 双向
工作温度: -25°C ~ 85°C
封装/外壳: 模块
包装: 散装
产品目录页面: 2809 (CN2011-ZH PDF)
其它名称: 398-1039
Current Transducer HX 03..50-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
All data are given with R L = 10 k W
Electrical data
I PN = 3 .. 50 A
Primary nominal
current rms
I PN (A)
3
5
10
15
20
25
50
Primary current
measuring range
I PM (A)
± 9
± 15
± 30
± 45
± 60
± 75
± 150
Primary conductor
diameter x turns
(mm)
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
Type
HX 03-P
HX 05-P
HX 10-P
HX 15-P
HX 20-P
HX 25-P
HX 50-P
Features
● Galvanic isolation between
primary and secondary circuit
● Hall effect measuring principle
● Isolation voltage 3000V
● Low power consumption
● Extended measuring range (3 x
I PN )
● Power supply from ±12V to ±15V
● Isolated plastic case recognized
according to UL 94-V0.
V OUT
R OUT
R L
V C
V C
Output voltage (Anarog) @ ± I PN , R L = 10 k W, T A = 25 °C
Output internal resistance
Load resistance
Supply voltage (± 5 %) 1)
Current consumption
± 4
< 50
≥ 10
± 15
< ± 15
V
W
k W
V
mA
Advantages
● Low insertion losses
● Easy to mount with automatic
handling system
Accuracy - Dynamic performance data
● Small size and space saving
● Only one design for wide current
ε
X Accuracy @ I PN , T A = 25°C (xcluding offset)
L Linearity error (0 .. ± I PN )
V OE Electorical offset voltage @ I P = 0, T A = 25°C
V OH Hysteresis offset voltage @ I P = 0
after an excursion of 1 x I PN
TCV OE Temperature coefficient of V OE
TCV OUT Temerature coefficient of V OUT (% of reading)
t r Response time to 90% of I PN step
BW Frequency bandwidth (- 3 dB) 2)
< ± 1 % of I PN
< ± 1 % of I PN
< ± 40 mV
< ± 15 mV
< ± 1.5 mV/K
± 0.1 %/K
≤ 3 μs
50 kHz
ratings range
● High immunity to external
interference
Applications
● AC variable speed drives
● DC motor drives
● Battery supplied applications
General data
Uninterruptible Power Supplies
(UPS)
T A
T S
m
Ambient operating temperature
Ambient storage temperature
Mass ...
Standards
- 25 .. + 85
- 25 .. + 85
8
EN 50178: 1997
°C
°C
g
● Switched Mode Power Supplies
(SMPS)
● Electrical appliances
Application domain
Note :
1)
2)
Also operate at ±12V power supples, measuring range reduced to ± 2.5 x I PN .
Small signal only to avoid excssive heating of the magnetic cores.
● Industrial
Page 1/3
110523/14 .
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
相关PDF资料
PDF描述
HY 20-P CURRENT TRANSDUCERS 20A 15V
HY 50-P SENSOR CURRENT 50A -+15V 6PIN
HY19-12LF COUPLER 90DEG 0.88-0.96GHZ 8SOIC
HY22-73LF COUPLER 90DEG 2.1-2.3GHZ SOT-6
HY92-12LF COUPLER 90DEG 0.88-0.96GHZ 8SOIC
相关代理商/技术参数
参数描述
HX50-P 制造商:LEM Holdings SSA 功能描述:ACDC 50A 4V 1% PS+/-15V
HX50-P/SP2 制造商:LEM Holdings SSA 功能描述:HX52-P/SP2 PCB current transducer
HX50-SP2 制造商:LEM 制造商全称:LEM 功能描述:Current Transducer
HX5103FNL 制造商:Pulse Electronics Corporation 功能描述:- Bulk
HX5104FNL 制造商:Pulse Electronics Corporation 功能描述:- Bulk