参数资料
型号: KSZ8863FLLI
厂商: Micrel Inc
文件页数: 42/106页
文件大小: 0K
描述: IC ETHERNET SWITCH 3PORT 48-LQFP
标准包装: 250
控制器类型: 以太网开关控制器
接口: MII
电源电压: 1.8V,2.5V,3.3V
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 48-LQFP
供应商设备封装: 48-LQFP(7x7)
包装: 托盘
配用: 576-3866-ND - BOARD EVALUATION FOR KSZ8863FLL
其它名称: 576-3750
Micrel, Inc.
KSZ8863MLL/FLL//RLL
January 27, 2014
4
Revision 1.5
Contents
Functional Diagram............................................................................................................................................................... 1
Applications........................................................................................................................................................................... 2
Pin Description and I/O Assignment ................................................................................................................................. 12
Pin Configuration ................................................................................................................................................................ 16
Functional Description ....................................................................................................................................................... 17
Functional Overview: Physical Layer Transceiver .......................................................................................................... 17
100BASE-TX Transmit ..................................................................................................................................................... 17
100BASE-TX Receive ...................................................................................................................................................... 17
PLL Clock Synthesizer...................................................................................................................................................... 17
Scrambler/De-scrambler (100BASE-TX Only) ................................................................................................................. 17
100BASE-FX Operation.................................................................................................................................................... 17
100BASE-FX Signal Detection ......................................................................................................................................... 18
100BASE-FX Far-End Fault ............................................................................................................................................. 18
10BASE-T Transmit.......................................................................................................................................................... 18
10BASE-T Receive ........................................................................................................................................................... 18
MDI/MDI-X Auto Crossover .............................................................................................................................................. 18
Straight Cable ............................................................................................................................................................ 19
Crossover Cable ........................................................................................................................................................ 20
Auto-Negotiation ............................................................................................................................................................... 21
LinkMD
Cable Diagnostics.............................................................................................................................................. 22
Access ....................................................................................................................................................................... 22
Usage......................................................................................................................................................................... 22
Functional Overview: Power Management....................................................................................................................... 22
Normal Operation Mode ................................................................................................................................................... 23
Energy Detect Mode ......................................................................................................................................................... 23
Soft Power Down Mode .................................................................................................................................................... 23
Power Saving Mode.......................................................................................................................................................... 23
Port based Power Down Mode ......................................................................................................................................... 23
Functional Overview: MAC and Switch ............................................................................................................................ 24
Address Lookup ................................................................................................................................................................ 24
Learning ............................................................................................................................................................................ 24
Migration ........................................................................................................................................................................... 24
Aging................................................................................................................................................................................. 24
Forwarding ........................................................................................................................................................................ 24
Switching Engine .............................................................................................................................................................. 27
MAC Operation ................................................................................................................................................................. 27
Inter Packet Gap (IPG) .............................................................................................................................................. 27
Back-Off Algorithm..................................................................................................................................................... 27
Late Collision ............................................................................................................................................................. 27
Illegal Frames ............................................................................................................................................................ 27
Full Duplex Flow Control............................................................................................................................................ 27
Half-Duplex Backpressure ......................................................................................................................................... 27
Broadcast Storm Protection....................................................................................................................................... 28
Port Individual MAC address and Source Port Filtering ............................................................................................ 28
MII Interface Operation ..................................................................................................................................................... 28
RMII Interface Operation .................................................................................................................................................. 29
MII Management (MIIM) Interface .................................................................................................................................... 32
Serial Management Interface (SMI).................................................................................................................................. 33
相关PDF资料
PDF描述
PIC16C505-04E/SL IC MCU OTP 1KX12 14SOIC
PIC16F676T-E/ST IC MCU FLASH 1KX14 W/AD 14TSSOP
PIC12LC509A-04I/MF IC MCU OTP 1KX12 LV 8DFN
PIC12LCE519-04/SM IC MCU OTP 1KX12 LV W/EE 8-SOIJ
PIC12CE518T-04I/SM IC MCU OTP 512X12 W/EE 8-SOIC
相关代理商/技术参数
参数描述
KSZ8863MLL 功能描述:以太网 IC 3-Port Copper 10/100 Ethernet Switch with 1x MII Interface (Lead Free) RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray
KSZ8863MLL-EVAL 功能描述:以太网开发工具 3-Port Copper 10/100 Ethernet Switch with 1x MII Interface - Evaluation Board RoHS:否 制造商:Micrel 产品:Evaluation Boards 类型:Ethernet Transceivers 工具用于评估:KSZ8873RLL 接口类型:RMII 工作电源电压:
KSZ8863MLLI 功能描述:以太网 IC 3-Port Copper 10/100 Ethernet Switch w/ 1x MII Interface (Industrial Grade) RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray
KSZ8863RLL 功能描述:以太网 IC 3-Port Copper 10/100 Ethernet Switch with 1x RMII Interface (Lead Free) RoHS:否 制造商:Micrel 产品:Ethernet Switches 收发器数量:2 数据速率:10 Mb/s, 100 Mb/s 电源电压-最大:1.25 V, 3.45 V 电源电压-最小:1.15 V, 3.15 V 最大工作温度:+ 85 C 封装 / 箱体:QFN-64 封装:Tray
KSZ8863RLL-EVAL 功能描述:以太网开发工具 3-Port Copper 10/100 Ethernet Switch with 1x RMII Interface - Evaluation Board RoHS:否 制造商:Micrel 产品:Evaluation Boards 类型:Ethernet Transceivers 工具用于评估:KSZ8873RLL 接口类型:RMII 工作电源电压: