www.clare.com
LBB110
Rev. 6
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25 C)
2
Parameter
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current* (Continuous)
Peak Load Current
On-Resistance
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
Conditions
Symbol
Min
Typ
Max
Units
-
-
V
L
I
L
I
LPK
R
ON
-
-
-
-
-
-
-
-
-
350
120
350
35
1
V
mA
mA
μA
10ms
I
L
=120mA
V
L
=350V
25
-
I
F
=5mA,V
L
=10V
I
F
=5mA,V
L
=10V
50V; f=1MHz
T
ON
T
OFF
C
OUT
-
-
-
-
-
3
3
-
ms
ms
pF
25
I
L
=120mA
-
I
F
=5mA
-
V
R
=5V
-
-
I
F
I
F
V
F
V
R
I
L
V
C/O
V
I/O
5
-
50
-
1.4
5
10
-
-
mA
mA
V
V
μA
pF
V
RMS
0.4
0.9
-
-
-
3750
0.7
1.2
-
-
3
-
*Note: If both poles operate simulataneously load current must be derated so as not to exceed the package power dissipation value.
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
(10 Seconds Max.)
DIP Package
Flatpack/Surface Mount
Package
Min
-
-
-
-
-
Typ Max Units
-
150
1
-
50
-
1
-
5
-
800
2
mW
mA
A
V
mW
3750
-40
-40
-
-
-
-
V
RMS
°C
°C
+85
+125
-
-
+260
°C
-
-
+220
°C
1
Derate Linearly 1.33 mw/C
2
Derate Linearly 6.67 mw/C